Chapter 3 Robot Debugging and Components Maintenance
Document Version V1.1.0 (03-07-2022)
39
equipment.
After replacing the controller, copy the configuration file of the
old controller into the new controller to avoid parameter loss.
In case of any problems in the controller, replace it in time by following the steps below:
Tools: Allen wrench (one set), straight screwdriver (2*75), anti-static gloves
Step 1
Disconnect all cables from the interface panel of the controller.
Step 2
Use Allen wrench to remove the fastening screws.
Step 3
Fix the new controller in situ, and connect the disconnected cable interfaces
one after another.
3.6 Replacement and maintenance of 48V relay module
At the time of removal and installation, set up a safety fence and
warning signs around the robot to prevent other workers from
incorrectly operating it.
Remove and replace the robot components only after the robot
is powered off.
The 48V relay module is provided separately, and users can fix
it with M3 screws according to the structural characteristics of
the equipment.
In case of any problems in the 48V relay module, replace it in time by following the steps
below:
Tools: Allen wrench (one set), a straight screwdriver (2*75), a cross screwdriver (PH2),
anti-static gloves
Step 1
Disconnect all cables from the interface panel of the 48V relay module.
Step 2
Use Allen wrench to remove the fastening screws.
Step 3
Install the new 48V relay module in situ, and connect the disconnected cable
interfaces one after another.
3.7 Replacement and maintenance of discharge resistor
At the time of removal and installation, set up a safety fence
and warning signs around the robot to prevent other workers
from incorrectly operating it.