43
NO.
Parameter Name
Setting Range
Default
f315
Output terminal function A of T1
0~255
40
a) Relay in OFF status
b) Relay in ON status
Figure 2.10 Description of relay status
Table 2.3 Description of output terminal function
Output
terminal
function NO.
Output
Status
Description
OFF
Output frequency ≤ lower limit frequency setting of f009
0
ON
Output frequency > lower limit frequency setting of
f009
OFF
Output frequency < upper limit frequency setting of
f008
2
ON
Output frequency = upper limit frequency setting of
f008
OFF
Output frequency < setting of f337
4
ON
Output frequency ≥setting of f337
OFF
Output frequency > (set fre f339), or < (set
frequency - f339)
6
ON
(frequency - f339) < output frequency < (set frequency
+ f339)
OFF
Output frequency >(f338+f339), or < (f338-f339)
8
ON
(f338-f339)
<
Output frequency
<
(f338+f339)
Output
terminal
function NO.
Output
Status
Description