106
e-23
Braking
resistance
overload
Improper
selection of
braking
resistance
Choose more
suitable braking
resistor for working
condition
Disable braking
resistor load protection
F527=2
e-24
Inverter
overheat
fault
Inverter’s
cooling fan does
not work.
Environment
temperature is
too high.
Certain
ventilation
opening is
blocked.
There is heat
source near the
inverter.
Reset the inverter’s
fault after cooling and
restart the inverter.
Expand the free
space around the
inverter; Remove all
heat sources near the
inverter to lower the
environment
temperature.
e-25
Motor PTC
overheatin
g fault
External PTC
embedded in the
motor winding
indicates
existence of
motor
overheating.
Correct motor
overheating.
Check whether PTC
is working properly.
Check logic input
functions 27 and 28.
Code of
fault
Type of fault
Possible cause
Measures
(troubleshooting)