135
NO.
Parameter
Name
Setting Range
default
WRT
User
setting
f304
Input
terminal
function for
LI4
23:Frequency UP signal
input from external
contacts
24:Frequency DOWN signal
input from external
contacts
25:Frequency UP/DOWN
cancellation signal input
from external contacts
26:inversion of trip stop
command from external
device
27:Thermal trip stop signal
input from external device
28:inversion of thermal trip
stop signal input from
external device
29:Forced switching from
remote to local control
30:Operation holding (stop of
3-wire operation)
31:Forced switching of
command mode and
terminal board command
32:Display cancellation of the
cumulative power amount
(kWh)
33:Fire-speed control
34:Coast stop (gate off)
35:Inversion of Reset
36:Forced switching of stall
prevention level 2
37:PID control integral value
clear PID control integral
value clear
38:inversion of PID error
signal
39~69:Not used
39:Forward
running
acceleration
deceleration curve 2
40:Reverse
running
acceleration
deceleration curve 2
0
●