QBD CDxxHC Скачать руководство пользователя страница 3

 

 

            

 

 

            QBD COOLING SYSTEMS INC. 

                                                                                                                                                      QBD.COM

 

 

 

 
 
 

 

-

 

Always  use  QBD  supplied  OEM  parts  only.  Use  of  non-OEM 
parts will not only void the warranty but may also lead to a fire, 
explosion, serious injury or death. 

       ------------------------------------------------------------------------------------------ 

-

 

Only  trained  and  certified  technician,  for  Hydrocarbon 
systems, should service these coolers.  

      ------------------------------------------------------------------------------------------ 

-

 

Use  extreme  caution  and  follow  all  local/regional  codes  for 
transportation or relocation of Hydrocarbon coolers.

 

 

1. 

DISCLAIMER  

Please  read  this  manual  carefully  before 
installing,  operating  and  servicing  this  QBD 
R-290 

Hydrocarbon 

cooler. 

Improper 

installation,  operation  and  maintenance  of 
cooler can cause damage to the cooler, fire, 
explosion, severe injuries or death.  

This  manual  must  be  kept  in  an  accessible 
location 

for 

easy 

reference 

during 

installation,  operation,  maintenance  and 
service. 

QBD  neither  assumes  nor  authorizes  any 
representative  or  other  person  to  assume 
for  it any obligation or liability in connection 
with the QBD product, its sale, operation or 
use other than such as is expressly set forth 
herein. 
 

Exclusions from Warranty Coverage 

QBD warranty does not cover: 

a)  Spoilage  of  products,  loss  of  sales, 

incidental,  indirect,  consequential  or 
special  damages,  or  any  injury,  loss, 
cost  or  expense  directly  or  indirectly 
sustained  in  connection  with  the 
Product, its sale, operation or use. 
 

b)  without  limiting  the  generality  of  the 

foregoing,  spoilage  of  products,  loss  of 
sales, incidental, indirect, consequential 
or special damages, or any injury, loss, 
cost  or  expense  arising  directly  or 
indirectly 

from 

fungi 

or 

fungal 

derivatives sustained in connection with 
the Product, its sale, operation or use. 

 

c)  glass  (Door  &  Side  Window)  or  light 

bulb  breakage  (Fluorescent  Tubes  or 
Light  Bulbs),  castors,  hinges,  magnetic 
gasket,  sliding  door  wheels,  (Header  & 
Header  Lens),door  tracks,  decals, 
(Power  Cord,  Starters)  and  parts  of 
normal wear and tear. 
 

d)  any  product  that  has  been  subject  to 

misuse,  neglect,  alteration,  tampering, 
accident,  or  to  any  damage  to  any 
product  caused  during  transportation, 
improper  installation  (except  when  the 
Product  is  installed  by  employees  of 
QBD),  flood,  fire,  water  damage, 
burglary, terrorism or acts of God. 

 

Limited Warranty 

QBD  warrants  to  the  original  purchaser  at 
the  location  of  original  installation  of  the 
Product that the Product is free from defects 
in  material  or  workmanship  under  normal 
use  and  service  for  a  period  as  defined  in 
warranty terms from the date of shipment.   

QBD’s  obligation  under  this  warranty  shall 
be limited to repairing or re

placing at QBD’s 

option,  any  part  of  such  product,  which 
proves  thus  defective  and  which  upon 
examination  by  QBD  and  to  its  satisfaction 
to  be  defective  shall  be  determined  to  be 
defective.    Notwithstanding  this  assumption 

Содержание CDxxHC

Страница 1: ...W 3K6 1 800 663 3005 TEL 905 459 0709 FAX 905 459 1478 QBD COM info qbd com Publication 47 0480 189 B V2 5 01 2017 R 290 COOLERS HC SERIES INSTALLATION OPERATION AND MAINTENANCE MANUAL CAUTION READ THIS MANUAL BEFORE INSTALLATION OPERATION AND OR SERVICING YOUR COOLER ...

Страница 2: ...URES FOR R 290 8 7 INSPECTION UPON DELIVERY 8 8 VISUAL CHANGES TO CD 3 0 9 9 ELECTRICAL SAFETY 11 10 RECOMMENDED ELECTRICAL PARTS FOR HC COOLERS 13 11 INSTALLATION 14 12 CASTER INSTALLATION 15 13 SHELF INSTALLATION 15 14 COLD CONTROL 16 15 WIRING DIAGRAM FOR CDxxHC DCxxHC COOLERS 18 16 LED LIGHTING 19 17 COOLING DECK REMOVAL ACCESS AND RE INSTALL 20 18 HC MODEL DOOR REVERSAL AND ADJUSTMENT 21 19 P...

Страница 3: ...tion with the Product its sale operation or use b without limiting the generality of the foregoing spoilage of products loss of sales incidental indirect consequential or special damages or any injury loss cost or expense arising directly or indirectly from fungi or fungal derivatives sustained in connection with the Product its sale operation or use c glass Door Side Window or light bulb breakage...

Страница 4: ... operation and servicing 3 In order to carry out service and repair on R 290 COOLER the service personnel must be qualified and trained to handle flammable refrigerants This includes knowledge on tools transportation of the compressor and refrigerant relevant regulations and safety precautions Also service must be performed in a well ventilated area and in compliance with the local regional nation...

Страница 5: ...tain average product temperature at 3 3 C 38 F follow temperature setting as indicated on rating plate inside the cooler Any change in setting could result in poor performance and or component s failure 14 QBD will not be responsible for poor performance component failure s damages or losses due to improper installation of the cooling deck electrical components cooler itself and or use of non OEM ...

Страница 6: ...flammable substance that may be present in the surrounding environment WARNING Indicates potentially hazardous situation which if not avoided may result in injury property damage and or cooler failure DANGER Indicates potentially hazardous situation which if ignored could result in death or serious injury property damage and or cooler failure CAUTION emphasise information which may cause cooler fa...

Страница 7: ...f products loss of sales incidental indirect consequential or special damages or any injury loss cost or expense directly or indirectly sustained in connection with the Product its sale operation or use This cooler is NOT intended for outdoor use or to be subjected to direct sunlight dampness high dust levels extreme heat and or cold temperature Ensure adequate ventilation around the cooler It sho...

Страница 8: ...ater for at least 15min Get medical attention Frostbite Try to warm up the frozen tissues and seek medical attention Inhalation Immediately move to area with fresh air If breathing has stopped give artificial respiration If breathing is difficult qualified personnel may give oxygen Get medical attention Refer to updated MSDS for more details 7 INSPECTION UPON DELIVERY Your cooler contains R 290 re...

Страница 9: ...ious injury or death Only trained and certified technician for Hydrocarbon systems should service these coolers Use extreme caution and follow all local regional codes for transportation or relocation of Hydrocarbon coolers 8 VISUAL CHANGES TO CD 3 0 Technicians are responsible to ensure these red sleeves are always present on access points as per UL 471 requirement ...

Страница 10: ...rtified technician for Hydrocarbon systems should service these coolers Use extreme caution and follow all local regional codes for transportation or relocation of Hydrocarbon coolers All QBD Hydrocarbon coolers are provided with multiple identification and hazard labels These can be located inside the cabinet and other visible surfaces of the cooler Please contact QBD technical support for more i...

Страница 11: ...eaker For personal safety this appliance must be effectively grounded at all times The power cord of this cooler is equipped with a three prong grounding plug which mates with a standard three prong grounding wall outlet receptacle to minimize the possibility of electric shock hazard from this cooler Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is eff...

Страница 12: ...tric circuit until all work is completed and all connections are tested CAUTION All units must be powered at their nominal operating voltages at all times The voltage should be within 10 of the nameplate voltage rating as overvoltage or under voltage could damage the cooler QBD is not responsible for the repair or replacement of failed or damaged components resulting from electrical power failure ...

Страница 13: ... parts only Use of non OEM parts will not only void the warranty but may also lead to a fire explosion serious injury or death Below is just to demonstrate some examples of difference in parts used in non R 290 vs R 290 systems CONTROLLER Please contact QBD Technical support for more information on controller for your particular cooler ECM MOTORS UL Approved Very High Efficiency Brushless Wider op...

Страница 14: ...N AND DOOR SUPPORT BRACKETS Always maintain the following EXTERNAL clearances for ease of installation door opening and proper air circulation o Top 2 o Hinge Side 1 1 4 o Non Hinge Side 1 2 o Back 3 Maintain a clearance of at least 2 feet in front of the grill to ensure free air flow from the refrigeration unit Cooler is designed for freestanding installation only It should not be recessed or bui...

Страница 15: ...fer plate required as caster top is directly in contact with the vase channel plate Shim plate may be required for leveling of cooler IMPORTANT NOTE QBD does not offer casters for PC8 PC8L models Do not use any third party casters kits For safety and stability of the cooler only use the supplier levelling legs Don t adjust the levelling legs beyond a Maximum Height of 1 2 1 2 inch on PC8xx coolers...

Страница 16: ...ontrol QBD Part 47 0520 255 The recommended setting is at 5 which will allow the cooler to operate between 38 42 F Temperature probe should be in the return air section This controller features voltage protection automatic defrost and energy saving logics DISPLAY INDICATORS This indicates the Evaporator Motor s is are running but the Compressor is off On initial power up there is an intelligent de...

Страница 17: ... 5 on CAREL Controllers Push the WRENCH button for 3 seconds to get to the settings mode Use the COLDER or WARMER buttons to adjust to the desired setting To save the new setting you MUST push and hold the WRENCH button for 3 seconds or until the controller returns to USE QBD doesn t recommend any temperature setting change without prior authorization Cold control is set at 5 for beverage storage ...

Страница 18: ... After using the cooler for 24 hours adjust the temperature control to the setting that is best suited for your needs NOTE If the cooler is unplugged or turned off you must allow 5 minutes before starting it or plugging it back in If you attempt to restart it in less than 5 minutes it may not restart and it may damage the compressor and VOID WARRANTY Turning the temperature control dial to OFF or ...

Страница 19: ...or relocation of Hydrocarbon coolers Ref No 47 0040 533 Please call QBD service for additional information if required Check for refrigerant leak before connecting or disconnecting power to unit 16 LED LIGHTING All HC coolers are installed with customized LED lighting for maximum product illumination high energy efficiency and convenient replacement option Check for HC leak prior to disconnecting ...

Страница 20: ...a fire explosion serious injury or death Only trained and certified technician for Hydrocarbon systems should service these coolers Use extreme caution and follow all local regional codes for transportation or relocation of Hydrocarbon coolers 17 COOLING DECK REMOVAL ACCESS AND RE INSTALL FOLLOW STEPS BELOW FOR COOLING DECK REMOVAL RE INSTALLATION ...

Страница 21: ... two keyhole slots and screws that hold the grill in place Use a Philips type screwdriver to remove the top right bracket while holding the door If there is a shim under the bracket remove it too Set the bracket aside but take care to hold the door Open the door slightly and lift it up firmly The spring would be released at the bottom Place the door on a flat non scratching surface Interchange the...

Страница 22: ...r to the left for Counter Top Model 1 Unplug the cooler and empty it 2 Don t remove the leveling legs 3 Use a Philips type screwdriver to remove the top bracket while holding the door If there is a shim under the bracket remove it as well Set the bracket aside while continuing to support the door 4 Open the door slightly and lift it firmly The spring will be released at the bottom 5 Tilt the coole...

Страница 23: ...aphic if required 14 Check door gasket for proper sealing and alignment 19 PREVENTIVE MAINTENANCE AND CLEANING INSTRUCTIONS Interior Exterior Cleaning Cabinet Check the area for any refrigerant leak before connecting or disconnecting power to unit Remove all products and shelves Never use acids chemical thinner gasoline benzene or the like for cleaning any part of the cooler Boiling water or benze...

Страница 24: ...e above procedures to reinstall the cooling deck Please make sure you connect the power supply lift the handles install the locking bar and fasten the two screws CD coolers only Never use any sharp tool for cleaning the condensing coil The cooler contains flammable refrigerant 20 REPLACE VS REPAIR FOR COOLING DECK 3 0 Replace swap the cooling deck under the following circumstances a Compressor fai...

Страница 25: ...igerant recovery cylinder Portable lighting If possible it is recommended that the cooler cooling deck be removed from its existing position to a controlled workshop environment suitable to conduct the repair safely Safety Checks Prior to conducting maintenance or service on R 290 coolers perform all necessary safety checks to ensure the risk of ignition is minimized Please comply with the followi...

Страница 26: ... during which R 290 refrigerant can possibly be released to surrounding space If brazing or welding is required this should be performed in an area detached from the cooler If this is not possible then the system should be fully evacuated using guidelines as outlined in QBD service documents Ventilated Area Ensure that the area is in the open or that it is adequately ventilated before breaking int...

Страница 27: ...e a tube cutter rather than a torch to remove the failed component as shown below Using a torch may cause a fire hazard especially if the refrigerant has not been completely discharged recovered If you must use a torch to remove the failed component of sealed system do so while running dry nitrogen continuously through the system Always use OEM parts only Use of non OEM parts will not only void th...

Страница 28: ...nt and then sealing it with brazing material or silver solder Improper sealing of the process tube may lead to leaks or a sudden release of flammable refrigerant 23 GUIDELINES FOR TROUBLE SHOOTING Symptom Possible Cause Solution Compressor starts and runs but short cycles on the overload protector Excess current passing through overload Low unstable voltage Overload failed Capacitor fault Excessiv...

Страница 29: ...ion line frosted Evaporator fan not working Overcharged system Determine reason or replace if required Correct the charge Leaking water Very humid conditions Blocked drain Door not sealed properly top door seal Clear blocked drains Repair replace door gaskets realign seal doors Evaporator freeze up Temperature controller set too cold Blocked restricted air flow Defective evap motor running at low ...

Страница 30: ...y also lead to a major fire explosion severe injury or death 4 Can I use add light switches in R 290 cabinet NO All electrical fittings must comply with UL 471 and must be explosion proof It is therefore recommended not to add any electrical switch in the cabinet LEDs provided with the cooler are compliant to UL 471 and must be replaced with OEM parts only 5 Can the same tools be used to service a...

Страница 31: ... void the warranty but may also lead to a fire explosion serious injury or death Only trained and certified technician for Hydrocarbon systems should service these coolers Use extreme caution and follow all local regional codes for transportation or relocation of Hydrocarbon coolers 25 QBD CONTACT INFORMATION ...

Отзывы: