QBD COOLING SYSTEMS INC.
QBD.COM
14
-
Always use QBD supplied OEM parts only. Use of non-OEM
parts will not only void the warranty but may also lead to a fire,
explosion, serious injury or death.
------------------------------------------------------------------------------------------
-
Only trained and certified technician, for Hydrocarbon
systems, should service these coolers.
------------------------------------------------------------------------------------------
-
Use extreme caution and follow all local/regional codes for
transportation or relocation of Hydrocarbon coolers.
11.
INSTALLATION
LOCATION & LEVELING
— INDOORS
ONLY!
-
Cooler must be leveled front to back and
side to side to ensure optimum
performance. Use leg -adjust for proper
leveling.
-
Improper leveling may cause cooler
door(s) to not close properly. This can
cause the evaporator coil to accumulate
frost and/or drain pan to overflow.
EXTERNAL
AND
INTERNAL
CLEARANCES, SHELF POSITION AND
DOOR SUPPORT BRACKETS
-
Always
maintain
the
following
EXTERNAL
clearances for ease of
installation, door opening and proper air
circulation:
o
Top .............….........2”
o
Hinge Side............. 1 1/4”
o
Non Hinge Side...... 1/2”
o
Back...................... 3”
-
Maintain a clearance of at least 2 feet in
front of the grill to ensure free air flow
from the refrigeration unit.
-
Cooler is designed for freestanding
installation only. It should not be
recessed or built-in.
-
Don’t locate cooler in close proximity to
high heat appliances such as fryers,
heating ranges and / or heating ducts.
-
Minimum
INTERNAL
clearances are
required for adequate air circulation
inside the cooler. Maintain internal
clearances between the beverages and
the cooler walls and door(s) as follows :
-
Clearance
-
Inches
-
Side wall
-
1/2
-
Rear wall
-
1/2
-
Front glass
door and
product
-
1
-
MUST
remove the door support
bracket(s)
before
installation.
(applicable for specific models only)
-
ALWAYS
use the door support
bracket(s) during transport and/or
changing locations.