QBD COOLING SYSTEMS INC.
QBD.COM
15
-
Always use QBD supplied OEM parts only. Use of non-OEM
parts will not only void the warranty but may also lead to a fire,
explosion, serious injury or death.
------------------------------------------------------------------------------------------
-
Only trained and certified technician, for Hydrocarbon
systems, should service these coolers.
------------------------------------------------------------------------------------------
-
Use extreme caution and follow all local/regional codes for
transportation or relocation of Hydrocarbon coolers.
12.
CASTER INSTALLATION
The cooler has a new design for caster
installation. It does not require a transfer
plate anymore.
Nut insert (to fit casters) is flush with the
bottom surface of base channel. This design
will allow caster top in firm contact with
cooler base channel. Hence, transfer plate
can be avoided.
No Transfer plate required as caster top is
directly in contact with the vase channel
plate. Shim plate may be required for
leveling of cooler.
IMPORTANT NOTE:
-
QBD does not offer casters for PC8**
/PC8L** models Do not use any third
party casters kits. For safety and
stability of the cooler, only use the
supplier levelling legs.
-
Don’t adjust the levelling legs beyond a
Maximum Height of 1/2`` (1/2 inch) on
PC8xx coolers.
-
DC6/DC7 models have option for
adjustable leg too.
13.
SHELF INSTALLATION
-
Cooler shelves (flat or gravity) and a
bag containing shelf support clips are
packed at the factory inside the unit.
-
In CD HC models (except CD10/12/20
HC), a bottom shelf must be installed on
top of the base step (return air duct).
-
Improper shelf clip installation may
cause shelf and/or product to fall which
could result in personal injury or
damage to the cooler.
-
Do NOT place solid packages on bottom
shelf to avoid poor cooling performance.