Fault Recovery Procedure
280B
Several errors can cause a fault condition, including:
•
147B
Emergency Stop engaged or an open door
•
148B
Low air pressure
•
149B
Exhaust fan failure
•
150B
UV Lamp failure
•
151B
Board processing failure
•
152B
Board Stop failure
281B
The following sections show examples of each of these errors, but not all the possible errors.
For a complete list of error messages, see the Error Messages section.
437B
Warning: If the Emergency Stop was activated because of system failure, DO NOT
disengage the Emergency Stop. Shutdown the system and have qualified personnel
repair the machine.
438B
Warning: The Module will be hot. Wait for the module to cool or wear protective
clothing.
Recovery Procedure for Emergency Stop or Open
Door
282B
If the operator uses one of the Emergency Stop push buttons or the machine encounters a
system error, this procedure should be used to return the machine to the Cycle Stop state.
1.
153B
Disengage the “
Emergency Stop
” button or close all doors.
2.
154B
Press the green “
POWER ON
” button.
Recovery Procedure for Low Air Pressure
283B
Low air pressure may cause the board stops to operate incorrectly. There is an air pressure
gauge on the main regulator with a low-pressure sensor. This is a gross check to make sure
the machine has air. It does not detect slight fluctuations in line pressure.
If the module has
this error, perform the steps below:
1.
155B
Make sure the red main air pressure valve is set to “
SUP
”.
2.
156B
Make sure the main air pressure regulator is set for 60-80 psi.