Recovery Procedure for Exhaust Fan Failure
439B
CAUTION: Only complete this step if the error was due to a fan overload.
1.
157B
Turn the main power switch off (Figure 2).
2.
158B
Open the main enclosure and press the reset button on OL-1.
3.
159B
Make sure the module is cool and remove all obstructions from the exhaust screen
inside the cure chamber.
4.
160B
Start the module and do the startup procedures (
5.
161B
Operate the fan in Manual mode to make sure it operates correctly.
Recovery Procedure for UV Lamp Failure
•
162B
Operate the UV Lamp that caused the fault in Manual mode. If the lamp does
not operate correctly, refer to the separate Heraeus UV literature.
•
163B
Open the front doors to check the LED status on the lamp systems.
Recovery Procedure for Board Processing Failure
1.
164B
Open the access doors.
2.
165B
Make sure no boards are jammed in the chains. Use caution as the module will be hot.
3.
166B
If there is a board jammed, wait until the module is cool, or wear protective clothing
to remove the board.
4.
167B
If a board was jammed, examine the module for a cause. If no reason can be found,
close the door and select the “Reset” icon.
Recovery Procedure for Board Stop Failure
1.
168B
Select the “
Reset
” icon.
2.
169B
Operate the board stops in Manual mode to make sure they operate correctly. Refer
to Table 3 in the Troubleshooting section for more information.