Spectra UV
Revision D
/
January 2022
Page 37 of 47
Reintroducing Unfinished Boards
284B
In fault situations, the PVA UV cure module shuts down all operations. If a board is not
completely cured, the operator must process the board again.
285B
To do this, restart Auto Cycle and put the unfinished board on the conveyor to activate the
first sensor in the process flow. For multiple boards, wait until the first board has cleared the
module before processing another one. Continue until all unfinished boards are cured. The
operator can then return to normal board processing.
440B
Note: The operator must be careful when activating any sensors. Any inadvertent
activation of a sensor may throw the program’s operations out of sync and most
likely generate an error. If something appears amiss, execute a Cycle Stop and then
restart the Auto Cycle to reset the program.