Spectra UV
Revision D
/
January 2022
Page 30 of 47
Process Settings
1.
117B
The current
Recipe Name
displays at the top.
2.
118B
The
Conveyor Transfer Speed
during board transfer displays.
•
119B
The range is 0.3–25 m/min (1 – 82.02 ft/min).
3.
120B
The
Conveyor Cure Speed
during curing process displays.
•
121B
The range is 0.3–5.8 m/min (1-19.03 ft/min)
•
122B
Select the speed you want to change.
•
123B
Push the “
CLEAR
” button on the keypad.
•
124B
Enter the necessary speed in feet per minute. No decimal is required. For
example, to enter 6.0 feet per minute, press “
6
”. To enter 6.5 feet per minute
press “
6
” and then “
5
”. Push the “
ENTER
” button. The new speed will take
effect immediately.
4.
125B
The Recipe will display which
Conveyor Processing Mode
is selected. Use the
arrows to scroll through the process modes (Full Processing, Safe Processing, Quick
Cure, and Passthrough). See
5.
126B
Use the
+ - Page
icons or the F2 and F4 keys to scroll through the Recipes.
6.
127B
Use the arrows on the screen or the “
F1
” and “
ESC
” button to scroll to the Setup-
Conveyor Process screen.
24B