Installation Guide / ComT 2.0: 5°, 10° and 15°
27
Code-Compliant Planning and Installation Guide V1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
6
PV ez-Rack Commercial Tilt Spacing Tables –
Only for the use of 15 degrees COMT
Type of Rail
ER-R-ECO (ECO Rail) and all other ECO rails
Type of Interface
ER-I-05 (Tin Interface)
Solar Panel Dimension
2 m x 1 m
Purlin Thickness
1.9 mm
Panel tilt angle against horizontal - 0° <
α
< 10°
TC 3
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.37
0.92
0.69
0.46
1.37
0.92
0.69
0.46
1.32
0.88
0.66
0.44
1.26
0.84
0.63
0.42
1.20
0.80
0.60
0.40
B
1.21
0.80
0.60
0.40
1.21
0.80
0.60
0.40
1.15
0.76
0.57
0.38
1.09
0.72
0.54
0.36
1.03
0.68
0.51
0.34
C
1.03
0.68
0.51
0.34
0.60
0.40
0.30
0.20
0.56
0.38
0.28
0.19
0.24
0.16
0.12
0.08
0.23
0.15
0.11
0.08
D
0.53
0.35
0.26
0.18
0.53
0.35
0.26
0.18
0.21
0.14
0.11
0.07
0.21
0.14
0.11
0.07
0.20
0.13
0.10
0.07
TC 2.5
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.32
0.88
0.66
0.44
1.26
0.84
0.63
0.42
1.20
0.80
0.60
0.40
1.20
0.80
0.60
0.40
1.15
0.76
0.57
0.38
B
1.15
0.76
0.57
0.38
1.15
0.76
0.57
0.38
1.09
0.72
0.54
0.36
1.03
0.68
0.51
0.34
1.03
0.68
0.51
0.34
C
1.03
0.68
0.51
0.34
0.56
0.38
0.28
0.19
0.56
0.38
0.28
0.19
0.23
0.15
0.11
0.08
0.23
0.15
0.11
0.08
D
0.49
0.33
0.25
0.16
0.49
0.33
0.25
0.16
0.20
0.13
0.10
0.07
0.20
0.13
0.10
0.07
0.20
0.13
0.10
0.07
TC 2
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.26
0.84
0.63
0.42
1.20
0.80
0.60
0.40
1.15
0.76
0.57
0.38
1.15
0.76
0.57
0.38
1.09
0.73
0.54
0.36
B
1.15
0.76
0.57
0.38
1.03
0.68
0.51
0.34
1.03
0.68
0.51
0.34
1.03
0.68
0.51
0.34
0.97
0.64
0.48
0.32
C
0.97
0.64
0.48
0.32
0.53
0.35
0.26
0.18
0.53
0.35
0.26
0.18
0.23
0.15
0.11
0.08
0.21
0.14
0.11
0.07
D
0.49
0.33
0.25
0.16
0.46
0.31
0.23
0.15
0.20
0.13
0.10
0.07
0.20
0.13
0.10
0.07
0.18
0.12
0.09
0.06
7
PV ez-Rack Commercial Tilt Spacing Tables –
Only for the use of 15 degrees COMT
Type of Rail
ER-R-ECO (ECO Rail) and all other ECO rails
Type of Interface
ER-I-05 (Tin Interface)
Solar Panel Dimension
2 m x 1 m
Purlin Thickness
1.9 mm
Panel tilt angle against horizontal - 10° <
α
< 20°
TC 3
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.09
0.72
0.54
0.36
1.09
0.72
0.54
0.36
1.03
0.68
0.51
0.34
1.03
0.68
0.51
0.34
0.97
0.64
0.48
0.32
B
0.91
0.60
0.45
0.30
0.91
0.60
0.45
0.30
0.91
0.60
0.45
0.30
0.85
0.56
0.42
0.28
0.85
0.56
0.42
0.28
C
0.79
0.52
0.39
0.26
0.46
0.31
0.23
0.15
0.46
0.31
0.23
0.15
0.18
0.12
0.09
0.06
0.18
0.12
0.09
0.06
D
0.42
0.28
0.21
0.14
0.42
0.28
0.21
0.14
0.17
0.11
0.08
0.06
0.17
0.11
0.08
0.06
0.14
0.09
0.07
0.05
TC 2.5
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.09
0.72
0.54
0.36
1.03
0.68
0.51
0.34
0.97
0.64
0.48
0.32
0.97
0.64
0.48
0.32
0.91
0.60
0.45
0.30
B
0.91
0.60
0.45
0.30
0.85
0.56
0.42
0.28
0.85
0.56
0.42
0.28
0.79
0.52
0.39
0.26
0.79
0.52
0.39
0.26
C
0.79
0.52
0.39
0.26
0.46
0.31
0.23
0.15
0.42
0.28
0.21
0.14
0.18
0.12
0.09
0.06
0.17
0.11
0.08
0.06
D
0.39
0.26
0.19
0.13
0.39
0.26
0.19
0.13
0.15
0.10
0.08
0.05
0.14
0.09
0.07
0.05
0.14
0.09
0.07
0.05
TC 2
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
Internal Intermediate Edge Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner Internal Intermediate
Edge
Corner
A
1.03
0.68
0.51
0.34
0.97
0.64
0.48
0.32
0.97
0.64
0.48
0.32
0.91
0.60
0.45
0.30
0.91
0.60
0.45
0.30
B
0.85
0.56
0.42
0.28
0.85
0.56
0.42
0.28
0.79
0.52
0.39
0.26
0.79
0.52
0.39
0.26
0.79
0.52
0.39
0.26
C
0.79
0.52
0.39
0.26
0.42
0.28
0.21
0.14
0.42
0.28
0.21
0.14
0.17
0.11
0.08
0.06
0.17
0.11
0.08
0.06
D
0.39
0.26
0.19
0.13
0.32
0.21
0.16
0.11
0.14
0.09
0.07
0.05
0.12
0.08
0.06
0.04
0.12
0.08
0.06
0.04
- Certification -