OS 315
43
Chapter 5:
PLUMBING SYSTEMS
5.1 Fresh Water System
GENERAL
The fresh water system consists of a potable water tank, distribution lines and a distribution pump. The pump
is equipped with an automatic pressure switch and is accessed through the starboard side of the mid-berth. An
in-line strainer located near the pump protects the system from debris. The tank is filled through a labeled deck
plate located on the gunwale.
DO NOT FILL THE SYSTEM WITH ANYTHING OTHER THAN WATER. SHOULD THE
SYSTEM BECOME CONTAMINATED WITH FUEL OR OTHER TOXIC FLUIDS, COMPO-
NENT REPLACEMENT MAY BE NECESSARY.
DO NOT CONFUSE FUEL FILL DECK PLATES WITH THE WATER OR WASTE FILL
DECK PLATES. THESE PLATES ARE ALSO LABELED ACCORDINGLY. IF GASOLINE
OR DIESEL IS ACCIDENTALLY PUMPED INTO THE WATER OR WASTE TANK, DO NOT
ATTEMPT TO PUMP IT OUT YOURSELF. WATER AND WASTE PUMPS ARE NOT DE-
SIGNED TO PUMP FUEL AND A FIRE OR EXPLOSION COULD RESULT. HAVE THE FUEL
PROFESSIONALLY REMOVED AND THE COMPONENTS OF THE FRESH WATER SYSTEM
REPLACED AS NECESSARY.
OPERATION
Fill the water supply tank slowly through the labeled deck plate. After filling the water tank, partially open
all faucets. The “Fresh Water System” switch at the helm should be "ON." Allow the pump to run until all
of the air is purged from the system and a steady stream of water is flowing from each outlet. Next, turn off
the faucets one by one. As the pressure builds, the pump will automatically shut off.
When properly primed and activated, the water system will operate much like the water system in a home.
An automatic pressure sensor keeps the system pressurized. If the system has been recently filled or has not
been used for an extended period, air bubbles may accumulate at the pump and the system may have to be
reprimed.
Whenever the boat is left unattended, the fresh water system switch should be placed in the “OFF” position.
DO NOT ALLOW THE FRESH WATER PUMP TO RUN DRY. THE FRESH WATER PUMP
WORKS ON DEMAND AND WILL NOT SHUT OFF AUTOMATICALLY WHEN THE TANK
IS EMPTY. THIS CAN RESULT IN DAMAGE TO THE PUMP. ALWAYS TURN THE WA-
TER PRESSURE SWITCH "OFF" WHEN THE FRESH WATER SYSTEM IS NOT IN USE.
WATER HEATER
The water heater is located below the passage leading to the mid-berth. All heaters have an AC element that
is thermostatically controlled at the heater and activated by a circuit breaker located in the AC panel. A high
pressure relief valve protects the system from excessive pressure. Always make sure all air is purged from
Содержание OS 315
Страница 2: ...OS 315 2 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 4: ...OS 315 4 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 6: ...OS 315 6 OperatorNotes...
Страница 8: ...OS 315 8 OperatorNotes...
Страница 10: ...OS 315 10 OperatorNotes...
Страница 58: ...OS 315 58 OperatorNotes...
Страница 64: ...OS 315 64 OperatorNotes...
Страница 74: ...OS 315 74 OperatorNotes...
Страница 90: ...OS 315 90 OperatorNotes...
Страница 98: ...OS 315 98 OperatorNotes...
Страница 106: ...OS 315 106 OperatorNotes...
Страница 114: ...OS 315 114 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 116: ...OS 315 116 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 117: ...OS 315 117 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 118: ...OS 315 118 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 119: ...OS 315 119 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 120: ...OS 315 120 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 124: ...OS 315 124 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 128: ...OS 315 128 THIS PAGE WAS LEFT BLANK INTENTIONALLY...