![Pulsar Measurement Greyline AVFM 6.1 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/pulsar-measurement/greyline-avfm-6-1/greyline-avfm-6-1_instruction-manual_1625414019.webp)
PULSAR MEASUREMENT
19
CUSTOM CHANNELS
Reset Data
Old data MUST be removed before entering data for a
new channel. Press
then press
to
Yes
and
press
to clear old data.
Max Height
Enter the maximum height of the channel.
Division
Divide the maximum height into equal increments
(maximum of 40) and enter this division value
(example 1”, 1 cm etc.)
Increment #
Enter the increment number if you want to edit a
previous entry or to skip entering widths for some
levels (Note: The custom channel will interpolate
widths between entry points).
Width
Enter the measured width of the channel at the level
shown (Note: To enter 0 width you must press
and
then
to store a 0 width data point).
Level
Displays the level of the channel for each increment
and width entry.
Note:
Custom channel data in equal width increments with variable height
measurements must be converted to the format shown above using the
“Channel Data Translator” PC software.
--
-----
Custom Channel
Type
Custom
Reset Data
No
Max Height
0.75 ft
Division
0.05 ft
Increment #
0
Width
0.000 ft
Level
0.000 ft
MAX
HEIGHT
10
9
8
7
6
5
4
3
2
1
0
WIDTH
INCREMENT #
DIVISION
LEVEL