INSTALLATION
2.4.3.2 Temperature Transmitter Wiring
HAZARDOUS AREA INFORMATION
The temperature transmitter is certified intrinsically safe for
use in Hazardous areas by TRL and is covered by EC-Type
examination certificate TRAC09ATEX11232X. The instrument
conforms to the standards EN60079-0:2006, En60079-
11:2007, EN60079-26:2007, EN61241-0:2006, EN61241-
11:2006 certification code II 1 G Ex ia IIC T4 Ga, Ex iaD 20
T135 °C Da, Tamb -20 °C to +85 °C
Before using the temperature transmitter in any hazardous
environment, ensure that personnel are completely familiar
with the above standards relating to the certification of this
instrument and also with the intrinsically safe apparatus
information in EN60079-14:1997 or equivalent codes of
practice in the country of installation.
If the temperature transmitter is not ordered together with
the analyzer, it is the user’s responsibility to make sure
that the temperature transmitter is compatible with the I.S.
barrier in the control unit.
Refer to ATEX/
QPS
/IECEx certificates for the dew-point and
temperature transmitters’ connection cable requirements
which stipulate maximum permissible mutual capacitance
and inductance to resistance ratio.
a. Cable connection to the temperature transmitter is made via the terminal
block (4) accessed by removing the terminal housing lid (2)
(Figure 19).
1
1
2
3
4
5
Figure 19
Temperature Transmitter Housing
b.
Ensure that the outer diameter of the selected cable is matched to an
EExe M20 cable gland (5). Unscrew the cable gland (5) and slide the cable
through the cable gland (5) and into the terminal housing (1) through the
cable entry (3).
Содержание Michell Instruments Liquidew I.S.
Страница 54: ...Liquidew I S User Manual 46 97092 Issue 5 3 September 2021 APPENDIX A Appendix A Technical Specifications ...
Страница 58: ...Liquidew I S User Manual 50 97092 Issue 5 3 September 2021 APPENDIX B Appendix B Serial Communications ...
Страница 63: ...Liquidew I S User Manual Michell Instruments 55 APPENDIX C Appendix C Modbus RTU Comms ...
Страница 65: ...Liquidew I S User Manual Michell Instruments 57 APPENDIX C ...
Страница 66: ...Liquidew I S User Manual 58 97092 Issue 5 3 September 2021 APPENDIX D Appendix D Hazardous Area Certification ...
Страница 69: ...Liquidew I S User Manual Michell Instruments 61 APPENDIX E Appendix E System Drawings ...
Страница 76: ...http www michell com www ProcessSensing com ...