WILDEN PUMP & ENGINEERING, LLC
10
WIL-19011-E-07
T R O U B L E S H O O T I N G
1) When there is a significant drop in the fluid discharge
pressure, there will be a noticeable release of air
through the small bleed hole in the air regulator
body. This is how the Equalizer
®
automatically adjusts
itself for optimal suppression. This is a good way
of verifying proper operation of the unit. If there is
a continuous discharge of air out of this hole during
steady fluid discharge pressure, the Equalizer
®
is not
functioning properly and should be inspected. The air
regulator body houses three (3) Glyd rings.
2) Fluid leakage around the clamp band area is normally
stopped by tightening the clamp band bolts. If
leakage continues, unit should be disassembled and
inspected.
3) Air leakage between the adapter plate and air chamber
requires tightening of four air chamber bolts on the
inside of the air chamber.
Содержание Wilden XSD Series
Страница 17: ...N O T E S...