Step 4
Set liquid chamber aside.
Step 5
Remove reducer bushing at top of
regulator.
Step 6
Loosen shaft assembly by using
adjustable wrench on outer piston
and 3/4” socket on shaft bolt inside
air regulator body. Turn counter
clockwise. One of two scenarios will
occur: outer piston will loosen from
shaft, or the shaft bolt will loosen
from shaft.
Step 7
In either case, this will allow the
removal of the inner and outer
pistons, diaphragm, shaft stop,
shaft, shaft stop washer and bolt.
Step 8
Inspect shaft for nicks or abrasion.
Small nicks can usually be dressed
out. If shaft is chemically attacked or
nicks are hindering operation, shaft
should be replaced.
Step 9
Disassembly of the air chamber
from the regulator adaptor plate
is needed only in the event of air
leakage.