WILDEN PUMP & ENGINEERING, LLC
6
WIL-19011-E-07
S e c t i o n 5
X S D 1 P E R F O R M A N C E
These charts show discharge head fluctuations for a
diaphragm pump with and without a dampener. By
reviewing the variation in pressure, the level of dampening
can be estimated for an application. For example, the head
pressure generated by a 25 mm (1”) pump operating at
6.89 bar (100 psig) air inlet pressure and 6.2 bar (90 psig)
head pressure varies between 1.7 bar (25 psig) and 7.2
bar (104 psig) resulting in a total pressure fluctuation of
5.5 bar (79 psig) for each stroke. When an XSD1/AAAA/
TNU/TF dampener is installed in the application, the
head pressure varies between 4.8 bar (69 psig) and 6.6
bar (96 psig) resulting in a pressure fluctuation of only
1.9 bar (27 psig). This results in a 67% reduction in head
pressure fluctuation.
XSD1 TNU
[4.1 bar (60 psig) inlet air / 3.4 bar (50 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
0
0.7 (10)
1.4 (20)
2.1 (30)
2.8 (40)
3.4 (50)
4.1 (60)
4.8 (70)
5.5 (80)
1 2
1 1.5 2 2.5 3 3.5
XSD1 BNS
[4.1 bar (60 psig) inlet air / 3.4 bar (50 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
4.8 (70)
4.1 (60)
3.4 (50)
2.8 (40)
2.1 (30)
1.4 (20)
0.7 (10)
0
XSD1 TNU
[6.89 bar (100 psig) inlet air / 6.2 bar (90 psig) discharge head]
Time
(sec)
0 0.5 1 1.5 2 2.5 3 3.5
Discharge Head
[bar (psig)]
1.4 (20)
2.8 (40)
4.1 (60)
5.5 (80)
6.9 (100)
8.3 (120)
0
0
1.4 (20)
2.8 (40)
4.1 (60)
5.5 (80)
6.9 (100)
8.3 (120)
1 1.5 2 2.5 3 3.5
XSD1 BNS
[6.89 bar (100 psig) inlet air / 6.2 bar (90 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
0
1.4 (20)
2.8 (40)
4.1 (60)
5.5 (80)
6.9 (100)
8.3 (120)
1 1.5 2 2.5 3 3.5
XSD1 BNU
[6.89 bar (100 psig) inlet air / 6.2 bar (90 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
Содержание Wilden XSD Series