WIL-19011-E-07
7
WILDEN PUMP & ENGINEERING, LLC
X S D 2 P E R F O R M A N C E
These charts show discharge head fluctuations for a
diaphragm pump with and without a dampener. By
reviewing the variation in pressure, the level of dampening
can be estimated for an application. For example
in reference to XSD2 BNS 100/90, the head pressure
generated by a 51 mm (2") pump operating at 6.89 bar (100
psig) air inlet pressure and 6.2 bar (90 psig) head pressure
varies between 0.4 bar (6 psig) and 7 bar (102 psig)
resulting in a total pressure fluctuation of 6.6 bar (96 psig)
for each stroke. When an XSD2/AAAA/BNS/BN dampener
is installed in the application, the head pressure varies
between 4.7 bar (68 psig) and 6.8 bar (99 psig) resulting in
a pressure fluctuation of only 2.1 bar (31 psig). This results
in a 68% reduction in head pressure fluctuation.
XSD2 BNS
[4.1 bar (60 psig) inlet air / 3.4 bar (50 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
0
0.7 (10)
1.4 (20)
2.1 (30)
2.8 (40)
3.4 (50)
4.1 (60)
4.8 (70)
0
1
2
3
4
5
0
1
2
3
4
5
XSD2 BNS
[6.89 bar (100 psig) inlet air / 6.2 bar (90 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
1.4 (20)
0
2.8 (40)
4.1 (60)
5.5 (80)
6.9 (100)
8.3 (120)
1 2 3 4 5
XSD2 TNU
[4.1 bar (60 psig) inlet air / 3.4 bar (50 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
0
1.4 (20)
2.8 (40)
4.1 (60)
5.5 (80)
0
20
40
60
80
100
120
0 1.5 2 2.5 3 3.5 4 4.5 5
XSD2 TNU
[6.89 bar (100 psig) inlet air / 6.2 bar (90 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
0 1.5 2 2.5 3 3.5 4 4.5 5
XSD2 BNU
[6.89 bar (100 psig) inlet air / 6.2 bar (90 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
0
1.4 (20)
2.8 (40)
4.1 (60)
5.5 (80)
6.9 (100)
8.3 (120)
1 2 3 4 5
XSD2 BNU
[4.1 bar (60 psig) inlet air / 3.4 bar (50 psig) discharge head]
Discharge Head
[bar (psig)]
Time
(sec)
0
0.7 (10)
1.4 (20)
2.1 (30)
2.8 (40)
3.4 (50)
4.1 (60)
Содержание Wilden XSD Series