1According to voltage requirement connect both sets of lines (thicker and thinner) K1 - K2 - K3 - K4 - K5 - and K6
on double row terminal block as described above.
11.
Ensure connections tightened, unused motor K lines must be isolated from ground and properly connected as
described in point 8.
12.
Properly set motor junction box cover.
13.
Remove previous voltage tags and marks on hoist and trolley.
14.
Replace voltage tags and marks with corresponding new voltage selected on hoist and trolley.
15.
Remove lockout/tagout and perform all corresponding inspection and testing as described in ASME B30.16-2
and ASME B30.17-2.