Specifications
39
Version 1.0
| 39 |
2.
Locate 9 black lines from motor labeled with yellow tags as K1 - K2 - K3 - K4 - K5 - K6 - K7 - K8 and K9.
3.
According to factory voltage black wires/lines connect as follows:
- 220V 60HZ all 9 lines connect into contactors relays in groups as follows:
K1, K4, K7 @U K2, K5, K8 @V K3, K6, K9 @W
- 380V 50HZ only 3 lines individually connect into contactors relays:
K1 @U
K2 @V
K3 @W
Lines K4 - K5 - K6 - K7 - K8 and K9 are separately connected.
- 44V 60HZ only 6 lines connect into contactors relays in sets as follows:
K4, K7 @U
K5, K8 @V
K6, K9 @W
Lines K1 - K2 and K3 are separately connected.
Notes:
•
Motor lines connected to contactors (U, V and W) are bridged between set of contactors.
•
Unused lines must be isolated from ground, properly connected, and secured behind contactors.
4.
According to voltage requirement connect lines K1 - K2 - K3 - K4 - K5 - K6 - K7 - K8 and K9 as described
above.
5.
Locate black triple voltage power transformer next to contactors. Unplug input (1 wire/line) and plug
according to voltage requirement. 220, 380 and 440V are displayed on transformer.
6.
Only for M5 units: Verify and replace rectifier with corresponding voltage. For voltages ranging
300~555V use rectifier model RH555 UHT 555V~0.75A For voltages ranging 198~270V use rectifier RB270
UHT 270V~0.75A.
7.
Ensure connections tightened, unused motor K lines must be isolated from ground and properly
connected as described in point 3.
8.
Open electric motor junction box on power trolley motor.
9.
Locate 9 black lines coming from motor labeled with yellow tags as K1 - K2 - K3 - K4 - K5 - K6 - K7 - K8
and K9.
10.
Preset black voltage wires/lines connect as follows:
- 220V 60HZ all 9 lines connect into double row terminal block in groups as follows:
K1, K4, K7 @U K2, K5, K8 @V K3, K6, K9 @W
- 380V 50HZ only 3 lines individually connect into double row terminal block: K1 @U K2 @V K3 @W
Lines K4 - K5 - K6 - K7 - K8 and K9 are separately connected.
- 44V 60HZ only 6 lines connect into double row terminal block in sets as follows:
K4, K7 @U K5, K8 @V K6, K9 @W Lines K1 - K2 and K3 are separately connected.
Notes:
•
Unused lines must be isolated from ground, properly connected and secured behind double row
terminal block.
Содержание PWR M5 Series
Страница 2: ...2 PWR 2 Version 1 0 This page intentionally left blank...
Страница 50: ...50 Wiring Diagram 50 Version 1 0 CONVENTIONAL HOIST WIRING DIAGRAM PWR PWRC...
Страница 51: ...Wiring Diagram 51 Version 1 0 51...
Страница 52: ...52 Wiring Diagram 52 Version 1 0...
Страница 53: ...Wiring Diagram 53 Version 1 0 53...
Страница 68: ...68 Technical Specs 68 Version 1 0 Chain Hoist...
Страница 70: ...70 Technical Specs 70 Version 1 0 Trolley...
Страница 73: ...Technical Specs 73 Version 1 0 73 PWR_M5 ELECTRIC CHAIN...
Страница 80: ...80 PWR 80 Version 1 0 C C A B B A...
Страница 92: ...92 PWRC_M5 92 Version 1 0 T Trolley Motor Width H Trolley minimum Headroom W Width R Trolley D Depth...