40
Specifications
| 40 |
Version 1.0
29
11.
According to voltage requirement connect lines K1 - K2 - K3 - K4 - K5 - K6 - K7 - K8 and K9 in double row
terminal block as described above.
12.
Ensure connections tightened, unused motor K lines must be isolated from ground and properly connected
as described in point 8
13.
Properly set motor junction box cover.
14.
Remove previous voltage tags and marks on hoist and trolley.
15.
Replace voltage tags and marks with corresponding new voltage selected on hoist and trolley.
16.
Remove lockout/tagout and perform all corresponding inspection and testing as described in ASME
B30.16-2 and ASME B30.17-2
PWR_i and PWR_M5i Series Triple Voltage Double Speed Electric Chain
Hoist
1.
Open electric box metal cover.
2.
Locate 12 black lines coming from motor labeled with yellow tags as: High Speed: 6 thicker lines K1 - K2 - K3
- K4 - K5 and K6. Low Speed: 6 thinner lines K1 - K2 - K3 - K4 - K5 and K6.
3.
Preset black voltage wires/lines connect as follows and repeat for thicker (High Speed) and thinner (Low
Speed) lines:
Содержание PWR M5 Series
Страница 2: ...2 PWR 2 Version 1 0 This page intentionally left blank...
Страница 50: ...50 Wiring Diagram 50 Version 1 0 CONVENTIONAL HOIST WIRING DIAGRAM PWR PWRC...
Страница 51: ...Wiring Diagram 51 Version 1 0 51...
Страница 52: ...52 Wiring Diagram 52 Version 1 0...
Страница 53: ...Wiring Diagram 53 Version 1 0 53...
Страница 68: ...68 Technical Specs 68 Version 1 0 Chain Hoist...
Страница 70: ...70 Technical Specs 70 Version 1 0 Trolley...
Страница 73: ...Technical Specs 73 Version 1 0 73 PWR_M5 ELECTRIC CHAIN...
Страница 80: ...80 PWR 80 Version 1 0 C C A B B A...
Страница 92: ...92 PWRC_M5 92 Version 1 0 T Trolley Motor Width H Trolley minimum Headroom W Width R Trolley D Depth...