Specifications
37
Version 1.0
| 37 |
PWR_ and PWR_M5 series Triple Voltage Single Speed Electric Chain
Hoist
1.
Open electric box metal cover.
2.
Locate 9 black lines coming from motor labeled with yellow tags as K1 - K2 - K3 - K4 - K5 - K6 - K7 - K8
and K9.
3.
Depending on factory voltage preset, black wires/lines should be connected as follows:
•
220V 60HZ all 9 lines are connected into contactor relays in set of 3 together as follows:
•
K1,K4,K7 @ U
•
K2,K5,K8 @ V
•
K3,K6,K9 @ W
•
380V 50HZ only 3 lines are individually connected into contactor relays:
•
K1 @ U
•
K2 @ V
•
K3 @ W
•
Lines K4 - K5 - K6 - K7 - K8 and K9 are separately all connected.
•
44V 60HZ only 6 lines are connected into the contactor relays in set of 2 together as follows:
•
K4,K7 @ U
•
K5,K8 @ V
•
K6,K9 @ W
•
Lines K1 - K2 and K3 are separately all connected.