2.
Using ACN button.
A full reset can also be done using the
acknowledge
button (ACN) on the front card by
following these steps:
▪
Restart the device by power cycling it.
▪
Press and hold the ACN button when the first LEDs light up (IRF etc.).
▪
After a while the EX LEDs are lit. Release the ACN button before they have counted
down entirely.
- Avoid a reset by pressing the ACN button until the device is in normal operation.
▪
The unit now resets the settings and then restarts.