Section 4  

Specifications and performance 

The most current information on the performance capability of these sensors is accessible at the Proteus 
web site at 

www.proteusind.com

.  

Flow Ranges 

 

Connection 

Part Numbers 

GPM 

LPM 

Brass 

Polypropylene 

Stainless Steel 

0.05 - 0.3 

0.2 

– 1.2 

¼” NPT 

0804BN03 

0804PN03 

0804SN03 

0.15 

– 2.0 

0.6 

– 7.6 

¼” NPT

 

0804BN2 

0804PN2 

0804SN2 

0.3 

– 4.5  

1.2 

–17 

¼” NPT

 

0804BN4 

0804PN4 

0804SN4 

0.3 

– 4.5  

1.2 

– 17 

9

/

16 

-18 SAE

 

 

 

0804SA4 

0.8 

– 10 

– 38 

3/8”NPT 

0806BN10 

0806PN10 

0806SN10 

0.8 

– 10 

– 38 

¾ -16 SAE 

 

 

0806SA10 

– 15 

3.8 

– 56 

½” NPT 

0808BN15 

0808PN15 

0808SN15 

1.3 

– 19 

– 72 

¾” NPT 

0812BN19 

0812PN19 

0812SN19 

1.5 

– 25 

– 95 

1

1

/

16

 

-12 SAE 

 

 

0816N25 

– 50 

11 - 190 

1” NPT 

0816BN50 

0816PN50 

0816SN50 

– 50 

11 

– 190 

1

5

/

16

 

-12 SAE 

 

 

0816SN26 

Liquid operating Limits

 

      Temperature  

- 40 to 100

o

C (-40 to 212 

o

F) with standard polysulfone faceplate.         

 
            -40 to 140

o

C                                               -40 to 284

o

Electronics must be thermally isolated from flow sensor at temperatures 
above 85°C and below dew point. 

      Pressure     

                     1720 kPa                                                      250 psi 

Kinematic Viscosity 

                     To 120 centistokes 

 

Wetted Materials 

      Flow Sensor Body  

304 Stainless Steel 

      Faceplate  

316 Stainless Steel 

      Sealing O-ring 

Viton ®                       (Other materials are available.) 

      Rotor   

Carbon fiber-filled Nylon 

      Rotor Shaft 

316 Stainless Steel     (Other materials are available.) 

 

Meter Performance 

     Voltage Output 

0

– 5 VDC for the maximum rated flow for each sensor type 

     Accuracy 

± 2 % of full scale 

 

Improved accuracy and linearity performance over smaller flow ranges 
can be achieved by specialized NIST-traceable calibration procedures.

 

 

     Linearity 

Better than ± 1% from 10 to 100% of nominal full scale 

     Reproducibility 

Better than ± 0.5% above 10% of nominal full scale  

 

Switch Performance 

     Trip Point Selection 

16 position changes trip points in steps of 6% of nominal full scale with fine 
adjustment between steps.   

     

Hysteresis / Dead Band 

< 5% of actual flow rate 

     Switch type 

Relay Closure 

     Relay rating 

SPDT 48 VDC, 1.0 A 

 

 

Electrical 

     Power Requirements 

24 VDC, 40 mA 

     Electrical Connection 

Plug type EDZ1550/8 with screw fastening of 8 conductors up to #16 gauge. 

     Remote Electronics 

Optional mounting locates electronics up to 30 ft from flow sensor.  Required for 

operation above 85°C. 

 

Flow Certification  

Standard products are provided with certificates of compliance.  Specialized 
calibration certificates are optionally available.  

Digital Display 

Optional panel mounted displays flow rate GPM or LPM on 3½ digits.  

Содержание 0804BN03

Страница 1: ...800 Series Metering Flow Switches TECHNICAL REFERENCE MANUAL...

Страница 2: ...2 3 How the flow sensor works 7 4 Specifications and performance 8 5 Product certifications 9 6 Installation 9 Mechanical 9 Electrical 13 7 Selecting Trip Points 14 8 Measuring Flow Rate 16 9 Digital...

Страница 3: ...ince 1978 Section 2 Features and Functions Flow ranges from 0 05 to 50 GPM 0 2 to 190 LPM Eight flow ranges are provided in the 800 Series in brass polypropylene or stainless steel NPT and SAE connect...

Страница 4: ...ely retrofittable in place of existing Proteus flow switches The distance between the 800 Series pipe or fitting connections is identical to those of previous Proteus flow sensors Stainless Steel face...

Страница 5: ...nsor may be HIGHER than is suggested in Table 1 Model Number Switch Position 0 1 2 3 4 5 6 7 8 9 A B C D E F 0804BN03 0804PN03 0804SN03 0 01 0 03 0 05 0 06 0 08 0 10 0 12 0 14 0 16 0 17 0 19 0 21 0 23...

Страница 6: ...x flow rate at selected trip point 10 Actual Flow 11 5 GPM Closed Open Red Less than flow rate at selected trip point Actual Flow 10 GPM Open Closed Multiple outputs provide control flexibility Elect...

Страница 7: ...oltage is continuously compared to a user selected trip point voltage When the measured voltage is above the trip point the built in relay remains in its active state If the measured voltage falls bel...

Страница 8: ...tainless Steel Sealing O ring Viton Other materials are available Rotor Carbon fiber filled Nylon Rotor Shaft 316 Stainless Steel Other materials are available Meter Performance Voltage Output 0 5 VDC...

Страница 9: ...ing or tubing is used the 800 Series metering flow switch may be supported by direct connection to the pipe or tubing Panel mounting To mount the sensor behind a panel two of the faceplate securing sc...

Страница 10: ...PTFE tape or PTFE based liquid sealants to provide leak tight and lubricated junctions at all connection points Real Tuff and Hercules are two of many suitable brands of PTFE based sealants Note It is...

Страница 11: ...more than 10 x pipe ID be used between the flow sensor and any up stream devices to minimize these effects Appropriate calibration procedures must be used to provide an accurate flow measurement with...

Страница 12: ...ontact with the face of the port using a wrench 2 Check to be certain that the O ring fits easily into the non threaded receiving area of the port and is not pinched Adjustable fittings 1 Ensure that...

Страница 13: ...ith the electrical circuit and control functions of the system in which the sensor is to be included should perform installation of this product Electrical inputs and outputs are provided at a single...

Страница 14: ...necessary use the screwdriver to turn the fine adjustment potentiometer so that the indicator is pointed towards the 12 o clock position 6 Peel away the protective label covering the 16 step switch a...

Страница 15: ...flow Section 9 Digital Displays Digital display units Digital panel display meters are available to provide a direct local display of flow rate in selected engineering units Each unit has a 3 digit LC...

Страница 16: ...you connect to the proper terminals Connection instructions 1 Strip connecting wire leaving approximately bare wire exposed Stranded wire should be tinned with solder 2 Insert the wire into the screw...

Страница 17: ...ugh the flow meter In most cases annual cleaning immediately prior to recalibration is sufficient Tools required Wrenches to disconnect the flow meter from your flow circuit A flat screw driver Soft c...

Страница 18: ...surface of the rotor If the bearing surface is worn or not round replace the rotor Inspect the stainless steel shaft If the shaft shows signs of scoring or other wear replace the shaft or the whole fa...

Страница 19: ...er the calibrated response of the sensor Please contact Proteus Technical Support if a specialized calibration is needed Note As described in the Plumbing Connections section on page 10 the response o...

Страница 20: ...bel will be attached to the flow meter Direct calibration against NIST traceable standards is optionally available Calibration by another laboratory The calibrating laboratory will issue certificates...

Отзывы: