Additional information about each alarm can be obtained via the configuration sub menu
<ALARM> –-> <ALARM INFORMATION> menu ID 3200 (accumulated count of the alarm type
and specific information for generic alarms). The event log configuration menu <EVENTLOG>
à
<VIEW> menu ID 8100 may provide information abut the exact start and stop time for each
type of alarm (requires that the alarm type has been routed to the event log by specifying Event
Log “on” for the alarm type in the configuration sub menu <ALARM> –-> <DEFINE ALARM
SYSTEM> menu ID 3100.
If an alarm is “unstable” and alternates between being active and inactive AND the
<CONFIGURE> – -> <AUTO OPEN ALARM WINDOW> (menu ID 5300) is set to “On” the
alarm display will be opened automatically as explained above. However, to allow uninterrupted
operation of the instrument via the front panel during repeated occurrence of an intermittent
alarm the alarm window will not open until five seconds after the last key-press of any front
panel key have taken place.
Status Window ’h1’ – The Test Signal Status Window
----------------------------------------
TEST SIGNAL ACTIVE
wv8
E
Single Carrier h1
----------------------------------------
This status window displays the current test signal configuration and is only available if a test
signal is active via the <TEST SIGNAL> – -> <SELECT TEST> sub menu Menu ID 6000. Note
that the test signal menu is only available if the TEST SIGNAL lock in the sub menu
<CONFIGURE> –-> <LOCK> menu ID 5100 is “OFF”.
4.3.4
Configuration Menu System
Two methods for accessing the configuration menu system exist. The first step is always to
push the
[EXECUTE]
button. This action will open the following display:
----------------------------------------
Entering Menus, Press Right Arrow
wv8
E
or EXECUTE for specific...
----------------------------------------
note: the display will close automatically after about 3 seconds if the user does not press the [RIGHT ARROW] key or the [EXECUTE] key
Top-level menu access
Pressing the
[RIGHT ARROW]
button during the above display mode will open the
configuration menu system at the default entry point (Transmission parameters, menu ID 1000).
For further details see paragraph 4.3.4.1
Context sensitive menu access
Pressing the
[EXECUTE]
button during the above display mode will open directly the
configuration sub menu that is related to the status menu window in which the activation of the
configuration menu system was initiated. For further details see paragraph 4.3.4.2. Note: when
entering the menu system via the context sensitive method it’s not possible to navigate to a
different menu without first exiting the configuration menu system (pressing the [UP] arrow key).