93-520-20 Issue 3.3
Page 28 of 60
CirrusPro Engineer’s Manual
3.2.19 Options
Buzzer:
The Buzzer is functional when this option is checked.
Update Logo:
This allows a customised logo to be downloaded to the display unit set to network
number 128. To change the logo on multiple units, each must be set to 128 in turn.
The file is opened using the standard Windows file menu. Use resolution 224 X 131,
1 Colour.
‘Send’ transmits the logo to the display unit. This must then be saved by entering the
network set up menu on the display unit and pressing exit. See Section 3.4.
Demo Mode:
The scanning rate is increased so there are no breaks between scans.
Note that the PC has no way of knowing a unit is in demo mode, so will always offer
the same display.
Stop Demo Mode:
Selecting this option stop demo mode operation.