Rebuilding a Disk Array (CLU)
Before you can rebuild, you must have a replacement or target physical drive of adequate capacity
for your disk array.
To rebuild a disk array:
1.
Main Menu
>>
Disk Array Management
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Background Activities
>>
Rebuild
Default source and target drives are shown with possible alternative choices.
4. To choose different drive, highlight the drive, press the backspace key to remove the current
number, then type a new number.
5. Highlight
Start
and press
Enter
.
Running Media Patrol on a Disk Array (CLU)
Media Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive.
If Media Patrol encounters a critical error, it triggers PDM if PDM is enabled on the disk array.