Making Global Physical Drive Settings (CLU)
All physical drive settings are made globally, except for setting an alias, which applies to individual
drives.
To make global physical drive settings:
1.
Main Menu
>>
Physical Drive Management
>>
Global Physical Drives Settings
2. Change the following settings as required.
• Highlight
Write Cache
and press the spacebar to
toggle between
Enabled
and
Disabled
.
• Highlight
Read Look Ahead Cache
and press the spacebar
to toggle between
Enabled
and
Disabled
.
• Highlight
MediumErrorThreshold
and press the backspace key to
remove the current value, then type a new smaller value.
• Highlight
DMA Mode
and press the spacebar to toggle
through UDMA 0 to 6 and MDMA 0 to 2.
3.
Press
Control-A
to save your settings.
See “Viewing Physical Drive Information” below to determine which functions your physical
drives support.
Medium Error Threshold is the number of bad blocks tolerated before the controller marks
the drive as Dead. The default setting is 64 blocks. A setting of zero disables the function.
When disabled, no drives are marked offline even when errors are detected.
113
Managing with CLU
Vess A6120 Product Manual
Содержание Vess A Series
Страница 14: ...System Hardware Overview System Components 2 Vess A6000 Series NVR Server Promise Technology ...
Страница 40: ...28 Vess A6120 Storage Server Appliance Promise Technology ...
Страница 47: ...8 8 8 35 System Hardware Assembly Vess A6120 Product Manual ...
Страница 123: ...111 Managing with CLU Vess A6120 Product Manual ...
Страница 128: ...116 Vess A6120 Storage Server Appliance Promise Technology ...
Страница 259: ...3 Click the Driver tab to see the driver version 247 Driver Installation and Update Vess A6120 Product Manual ...