July 2018
4-65
4.3.5
Amplitude Commands
Name
meas:refl:unit
Description
Sets the reference level unit
Syntax
meas:refl:unit
{1/2/3}
Query
Syntax
meas:refl:unit?
1 dBm
2 dBmV
Parameter/
Return
parameter
3
dB
µ
V
Query
example
meas:refl:unit?
>1
The reference level unit are dBm.
Name
meas:refl
Description
Sets or queries the reference level.
Syntax
meas:refl <refl>
Query
Syntax
meas:refl?
Parameter
<refl>
Reference level in the currently selected unit (from
the meas:refl:unit command).
Return
parameter
<refl>
Returns reference level and unit.
Example
Meas:refl 10
Sets the reference level to 10 dBm (for unit = dBm).
Query
example
meas:refl?
>10 dBm
4.3.6
Marker and Peak Search Commands
Name
meas:mark:on
Description
Sets or queries which markers are turned on.
Syntax
meas:mark:on {<NR1>/all}
Query
Syntax
meas:mark:on <NR1>?
Parameter
<NR1>
all
Marker number 1
~
5.
All markers.
Return
parameter
ON
OFF
The selected marker is on.
The selected marker is off.
Example
meas:mark on 1
Turns marker 1 on.
Query
example
meas:mark 1?
>OFF
Содержание AE-366B
Страница 1: ...AE 366B SPECTRUM ANALYSER 0 MI2007...
Страница 8: ......
Страница 57: ...July 2018 3 49 Figure 48 Average Off Figure 49 Average On 8x...