6.1.1 Setting the Height Limit to a Known Height - Continued
Maximum
Equipment Height
= 5.46m
In this example the maximum equipment height
is referred to the bucket pin.
<<<<LIMIT>>>>
! ARM TOO HIGH
The Height monitoring mode is now active, any piece of equipment which
intrudes into the set Height Limit will cause the relevant alarm and motion cut
condition to occur. Variable height limit is not active with key switch in 3.7m or
4.7m positions.
Ensure that the correct limit is selected and that it alarms correctly.
PRESS
[ENTER]
The system may be in alarm mode until
the equipment is lowered from the SET
height. The VAR lamp will now be lit on
the lamp bar.
Hgt MAX = 5.46
[ADJ
◄►
] [ENTER]
THE display will show the current set height
Limit.
Use the
◄
(MODE) and
►
(TEST)
buttons to adjust the set height to the
required value.
Press [ENTER] to
set height limit
The system will return to the height
setting screen if the machine is not in an
alarm condition or if the equipment is
lowered out of an alarm condition.