Error Conditions
EA
Heightmaster
+
software constantly checks for the presence of all attached sensors and if they are not detected then the display indicates
the problem component. This will indicate if the sensor is missing, damaged, or that there is a fault with interconnecting CAN bus cable. If an
error condition is displayed halt any operation, seek service immediately and do not continue operation until the fault has been remedied.
The failure message is shown on the lower line of the current active display. If more than one sensor fails then the Fail messages will scroll.
Boom sensor not detected.
Artic sensor not detected.
Arm sensor not detected.
Height = 6.07m
ARM FAIL!
Height = 6.07m
ARTIC FAIL!
Height = 6.07m
BOOM FAIL!
Height = 6.07m
RELAY SUPPLY!
Power not detected to Combi Box relays.
Height = 6.07m
COMBI FAIL!
Combi Box not detected.
Height = 6.07m
PROX FAIL!
Proximity switch failure or proximity switch mismatch. See test section 1.3.1 for
further information