6. Operation
Projekt Elektronik
MESS - UND REGELUNGSTECHNIK GMBH
Page 43
6.3.3.13 Command “inttime” or “time”
command:
inttime [time]
time [time]
without
parameter
shows the current measuring time in milli-seconds
with parameter
sets the measuring time to the given value (interpreted
as milli-seconds, rounded to a multiple of 100 ms)
parameter
100
≤
time
≤
25500
see also section 6.3.1.13 Key “time” – Measuring Time
examples:
time
integration time is 500 ms
time 1250
integration time is 1300 ms
6.3.3.14 Command “keys”
command:
keys [{on|off}]
without
parameter
shows if the keypad is locked or not
with parameter
switches keypad on (unlocked) or off (locked)
After switching the device off and on again, the keys are
unlocked.
parameter
on, off
examples:
keys
keys are unlocked
keys off
keys are locked