Prodys S.L. Tel: +34 91 6896880
Fax: +34 91 6943777
Email:
Web:
www.prodys.com
Page 22
The following configuration window will appear:
Picture 17. IP Menu.
There are two different options: Either to get the IP address automatically from a
DHCP server when available, or to set up these IP parameters manually. In the
example above, we are configuring them manually. Optionally, the DNS protocol
can be configured. It allows using domain names instead of IP addresses when
establishing calls.
NOTE
: When the unit is configured to get the IP address automatically from a
DHCP server, if no DHCP server is available in the network, the unit will try for a
while to get it, indicating the message ‘Negotiating DHCP’ on the Program and
TalkBack connection bars on the main menu page and, after that, the default IP
address and netmask will be assigned automatically: 192.168.100.100 /
255.255.255.0.
LAN1
:
RJ-45 connector on the rear side; 10/100/1000BT Ethernet interface.
Default interface for streaming and remote control.