H - I - J
PROGRAMMER’S MANUAL
V8.94.11-
- 82 -
Regulation on rotation speed, using IRE
Let the IRE be of 1000 pulse/revolution and the maximum rotation speed 5000.
The rotation speed should be adjustable between 50 and 3000,
The rotation speed to be kept should be 2000.
The motor should have two poles.
Remark: upon the maximum rotation speed, 5000 corresponds to 100%
Submenu
Setting
operation mode selection
regulation
regulation reference signal
40%
source of the regulation ref. signal
terminal
type of the regulation
normal
regulation reference signal maximum
60%
regulation reference signal minimum
1%
source of the feedback signal
IRE rotation
terminal control
yes
digital input 1 type selection
N
digital input 2 type selection
N
1000
5000
nominal rotation speed
2920
86 Hz
1 Hz
frequency inhibit limit
105 Hz
0,5
(integration time)
100ms
(differentiation time)
100ms
(diff. element overdriving factor)
0,5
For rotation speed regulation, "PI" or "PID" is the most proper regulation type.
Setting of the PID parameters depends on the system, they have always to be adjusted to the actual requirements.
To maintain the high dynamics and avoid swingings be especially careful at setting Td and Ad!
Commands start, stop and directions as well as changing the regulation reference signal can be effected from the
terminal
i
At setting fmax consider the rotation speed of the motor belonging to its nominal frequency and set the
maximum frequency to a value at which the adjustable maximum rotation speed can still be controlled
securely! (Allowance for the slip)
Содержание V3D Series
Страница 1: ...H I J frequency converters programmer s manual from software version V8 94 11 onwards P Since 1984...
Страница 2: ......
Страница 85: ...H I J PROGRAMMER S MANUAL V8 94 11 85 User settings Submenu Explanation Setting Unit...
Страница 86: ...H I J PROGRAMMER S MANUAL V8 94 11 86 Notes...
Страница 87: ......