H - I - J
PROGRAMMER’S MANUAL
V8.94.11-
- 34 -
Submenu
Explanation, further submenus
Values
Default setting
Unit
4-8
logical control
source
This parameter permits the source of the Start/Stop, Direction and Jog inputs to be selected.
i
The above signals in default setting are valid from the terminal blocks. For terminating
them the input(s) have to be reconfigured to an other function or to „N”!
4-8-1 terminal control
Whether a logical control signal can be given out
from the lower four buttons of the terminal (jog,
direction, start, stop)
no
yes
no
4-8-2 CAN control
Whether a logical control signal can arrive through
CAN bus. If in start mode, the signal ceases on the
bus, the equipment stops with error!
no
yes
no
4-9
logical param.
Setting further parameters of the digital inputs.
4-9-2 motor potentiometer
4-9-2-1 up time
In case of control, the rise time for the
reference signal from 0 to fmax (or fnom).
In case of regulation, the rise time for the
reference signal from 0 to 100%
In case of modification, the rise time for
the modification signal from 0 to 100%.
0,0 - 1000,0
10,0
s
4-9-2-2 down time
In case of control, the fall time for the refe-
rence signal from fmax (or from fnom) to 0.
In case of regulation, the fall time for the
reference signal from 100% to 0.
In case of modification, the fall time for the
modification signal from 100% to 0.
0,0 - 1000,0
10,0
s
4-9-2-3 clear
Zero setting of the value of the motorized
potentiometer.
ENC0cmd: At activating IREpos0 input
selected to any digital input, the value of
the motorized potentiometer will be set to
zero.
no
start up
by start
change direction
ENC0 cmd.
no
4-9-2-4 stop
Whether a stop in the control could be
given
out
with
the
motorized
potentiometer. In case of yes, if the control
reference signal set with the motorized
potentiometer is in minimum position and
a down command occurs again, this will
effect stop, and the motor stops. In this
state, on an up command of the motorized
potentiometer, the equipment goes in start
state and the motor starts with the
minimum frequency.
no
yes
no
4-9-3 DC brake current
If the DC brake is operated with the activation of
the digital input.
0 - Inominal
0,0
A
4-9-5 inp. filter
The time of filtering the digital inputs.
The value of the input will only be accepted, if it
has not changed within the preset time.
2 - 32
32
ms
4-10
fix start
Whether the ‘ready for operation’ state of the
equipment should mean start at the same time.
no
yes
no