12. Events menu
The event log can store 256 events along with the belonging point of times.
Event with number 0 i
s the latest one, the earlier events can be accessed with the „
” button.
Date display:
•
In case of Hungarian language: YYYY.MM.DD
•
In case of English language:
DD/MM/YYYY
The events that can be stored:
•
mains switch off and on depending on the state of menu item
•
occurrence of start, stop events depending on the state of menu item
•
occurrence of an external event from a digital or virtual input
•
the temperature of the heat sink reaches 60°C.
(in this case also cooling back of the heat sink will be entered in the
log, at reaching 55°C)
12 Events 1
Switch on
2007.06.05 0
16:31:05 34h
Equipment identifier
(1)
Operation hour 1
(34h)
Time
(2007.06.05 16:31:05)
Number of event
(0)
Name of event
(Switch on)