23
© 2014 Proceq SA
Tap to switch among
different views.
Two diameters and two NRC-
spacings (if set) are shown.
Left of / it’s the value of the
SX (scanning in X-direction
of the rebars running in
Y-direction), right of / it’s the
value of the SY (scanning
in Y-direction of the rebars
running in X-direction).
Either cover, diameter or
signal strength spectrum is
displayed.
Tap to switch among
different views.
Tap on
to change the global diameter of the active layer (SX or SY)
Figure 24:
Cross-Line Views: Cover, Diameter, Signal Strength
In the signal strength spectrum view two sliders are shown on the right.
•
With the O-slider (Offset) the signal strength range is set (from full
actual signal strength range to higher strength only).
•
With the G-slider (Gain) the signal strength resolution is set. The
signal strength is accordingly displayed in colors from full color
spectrum to part of it only, e. g. blue to violet only.
Three demo files are stored on the Profometer PM-6 Touchscreen in the
explorer under Demo Files and the document “Profometer PM-650 Demo
Files Tutorial.pdf” under Information\Documents.
Try out different slider positions to get familiarized with the display of the
signal strength color spectrum, e. g. the extreme positions:
O
- and
G
-slider lowest position:
Full color spectrum, full Signal
Strength range (of actual meas-
urements)
O
- and
G
-slider highest position:
Full color spectrum, highest
Signal Strength (shallower re-
bars) only
O
- highest,
G
-slider lowest position:
Blue/violet only, highest Signal
Strength (shallower rebars) only
O
- lowest,
G
-slider highest position:
Only grey color displayed, Sig-
nal Strength beyond actual one
To sharpen the color spectrum set “Sharpen”.