21
© 2014 Proceq SA
It is a Single-Line View from measurements done in the Multi-Line View,
because at position
10
the
1
refers to the measuring row displayed. Tap
on
10
to display the Single-Line View of the next row.
Tap to switch among
different views.
Figure 18:
Single-Line View with Signal Strength Curve
The spacing among the rebars as well as the distance from the start line
to the first rebar and from the last rebar to the end line are displayed
as figures in the unit set, but only if the spacing on the screen is large
enough. If not shown zoom in until the figures appear.
For more details like changing a diameter refer to Single-Line Mode in
chapter “3.5 Measurement Modes and Storage of Data”. To set a new
diameter you may have to measure it first at the particular location of the
structure in the Locating Mode and set it manually.
Multi-Line View
PM-630
PM-650
The Multi-Lline View can be displayed only if measurements have been
done and stored in the Multi-Line or Area-Scan Mode. It is a plan view, in
most cases of the first layer rebars. A Multi-Line View of the second layer
– main layer in columns and girders – may also be of interest.
Tap to switch among
different views.
Figure 19:
Multi-Line View with cover values displayed
Tap to switch among
different views.
Figure 20: