Blower (Standard with the optional generator)
The blower is located inside the bilge and helps keep fresh air circulating in the bilge area. You should
periodically check to make sure that the blower is working properly. First, confirm that the blower hoses are
connected and the blower itself is secured. Second, locate the blower switch inside the cabin on the starboard
cabin wall and press the switch to the on position. Then, go back to the bilge area and listen to hear if the blower
is running. The exhaust vents are located on the outside of the transom on the port and starboard sides. Check
to ensure that air is blowing out of the vents. When finished, go back into the cabin and turn the blower switch off.
Blower
Blower Switch
Blower Exhaust Vent
Generator – 7.0 kw Gas with Carbon Monoxide Detector and Auto Shut Off (Optional)
If you have selected the optional gas generator, your vessel will come equipped with a remote start/stop for the
generator, an hour meter, blower switch and 2 carbon monoxide detectors (one is installed in the V-berth of the
main salon and another in the mid berth.
WARNING: The switch for the blower is installed next to the AC/DC panel and should be turned
on for four (4) minutes prior to starting your engines or the generator to ensure that the bilge is
free from any gas fumes. The blower vents are located on the inside wings of the euro
transom/dive platform.
The generator is installed in the aft area of the bilge and can be started either direct from the generator or
remotely from the AC panel in the cabin.
Before attempting to operate the generator, the boat must be in the water or have some type of water flushing
system going into the generator water pick up. The generator seacock is mounted below the port side hatch in
the berth of the mid cabin. Inspect the seacock and ensure that it is open and that the hoses are all connected.
The seacock is open when the lever is in the vertical position. Then,
At the remote control panel for the battery management system (installed on the console), press the
house battery switch forward to the on position
Go into the cabin, locate the AC/DC panel and move the generator toggle switch to the on position.
Locate the blower switch (installed next to the AC/DC panel) and turn it on. After allowing the blower to
run for a few minutes and circulate fresh air throughout the bilge, the generator can be started up.
Starting the Generator from the Main Unit - You can start the unit directly from the generator using the
manufacturer’s instructions below: