22
`
Table 8 shows a list of the codes of the alarms, their names and useful information with recommendations.
Table 8 List of the alarms
20. REMOTE CONTROL
The panel has an integrated receiving device for infrared remote control (Firg.13)
Fig.13 Remote infrared control
The commands from the remote control are performed only if the START screen or the selection screen are displayed.
The selection of a degree of power is applied only after the fireplace is kindled successfully and if the ECO mode is off.
CLEANING AND MAINTENANCE
Before performing any maintenance or cleaning operation of the fireplace, take the following safety measures:
·
Be sure that all parts of the fireplace are cold.
·
Be sure that the ash is entirely cold.
·
Don't forget the key to be in position “OFF”.
·
Be sure that the plug has been removed from the socket in order to avoid contact out of carelessness.
Follow carefully the regulated instructions for cleaning. Failure to observe these instructions can cause problems in the operation
of the fireplace
When cleaning, use protective gloves.
To clean from ash on the floor of the firebox and the walls, surfaces of the combustion chamber, it is suitable to use an ordinary
brush of middle size.
Most effective and final cleaning turns out by using a specialized vacuum cleaner to clean fireplaces, with a container.
The lack of cleanness can prevent the startup and the normal, effective operation of the fireplace.
Daily cleaning
The same must be provided also before each lightning.
·
Cleaning of the grate
Open the door of the combustion chamber. Raise the grate and shake it off in the opening to the ashpan. If there is accumulated
ash, push it with a brush to the same opening. Place the grate very carefully and exactly in its place until support without blocking.
·
Clean the glass pane very carefully. It is resistant to temperature shocks but is sensitive to mechanical forces–stroke,
pressure, etc. Wipe it with damp cloth or wash with cleaning detergents and water.
·
Clean the heating surfaces behind the combustion chamber. They aren't accessible; therefore their cleaning is done
with an integrated mechanism. They are two scrapers and proceed as follows:
·
Remove the top decorative cover by lifting. Under it you can see the clamping ends. Pull them upward
and by moving up and down, five or six times, the surfaces are cleaned.
Cleaning the ashpan
The fireplace is equipped with an ashpan, which has a very big size. When using quality pellets, the ash from the ashpan
can be thrown away once monthly. If it is necessary to remove the ash more often, usually that means that pellets of bad quality
are used.
Seasonal cleaning and preventive maintenance
Besides the operations included in the daily cleaning, after the end of the season one complete and extensive cleaning is
necessary.
If you have some difficulties, you can contact the seller who is committed to the service maintenance of the product.
Cleaning the entrance to the flue fan.
Code:
Kind of the alarm
Information
A01
Ignition Failed
Clean Brazier and Restart
A02
Flame Shut Down
Fill Pellet Tank
A03
Pellet Tank Over -Temperature
See instruction manual
A04
Fumes Over-Temperature
See instruction
A05
Fumes Pressure Switch Alarm
Remove a Possible Obstruction
A08
Fumes Extractor Error
Call Assistance
A09
Fumes Temp. Sensor Error
Call Assistance
A10
Pellet Igniter Error
Call Assistance
A11
Pellet Feeder Error
Call Assistance
A13
Electronic MotherBoard Error
Call Assistance
A18
Water Tank Over -Temperature
See instruction manual