On the top line the room temperature and the current time are shown.
The room temperature and the temperature of the water are toggled on the display – in 5 seconds for the room temperature and 2 seconds for the
temperature of the water. (see Fig.3)
Fig. 2 – Main screen 1
Fig. 3 – Main screen 2
The current state (condition) of the fireplace is shown in each 2 seconds on the bottom line – the active functions (Table 1) or the active alarm conditions, it
there are any.
Table 1 – Messages displayed on the Main screen
*This message is displayed only if the option ECO is enabled.
**This message is displayed only if at the moment an alarm is enabled.
For all screens the background light of the display is maintained in a maximum degree.
If for 10 seconds no button is pressed, the display returns to the initial (home) screen (see Fig. 2). After 30 seconds the light turns off. When the backlight
of the display is turned off, pressing a random button switches on again and the selection screen appears (see Fig. 4).
3. IGNITION (or SWITCHING OFF) OF THE FIREPLACE
The ignition (or the switching off) of the fireplace is achieved by pressing and holding of button 5 (
ON/OFF
) on the panel.
4. MAIN FUNCTIONS
When pressing any of the buttons 1-4 on the panel the Selection screen is displayed (see Fig.4) and adjustment of the main parameters is possible – the
power of the fireplace and the room temperature.
Fig. 4 – Selection screen
Function
Displayed text
IGNITION
ON
SHUT DOWN
OFF
SHUT DOWN AFTER BLACKOUT
Controlled heater current status
IGNITION AFTER BLACKOUT
Crono mode active
Chrono Prog.
Sleep mode active
Sleep 12:30 AM (set time)
"Eco" active
Eco is Active*
Alarm conditions active
Alarms **
·
Button Mode toggles the modes from manual to automatic
·
The advanced functions are selected by button Menu.
·
The button 2 Temp/Fire changes the values of the temperature and the power depending on the selected operational mode.
·
When pressing the button ON/OFF the screen returns back to the home screen.
18