21
12.BACKLIGHT
The option backlight allows the user to set the time and the level of backlight of the display, used on the START screen. Choosing On, the display will
remain lit all the time. The other positions adjust the time when the backlight is on.
13. TEMPERATURE °C AND °F
The option Temperature °C and °F allows the user to choose the unit of measurement for temperature.
14. CORRECTION OF THE PERFORMANCE OF THE AUGER (Pellet recipe)
The Option “Pellet Recipe” allows the user to change the working cycle (performance of the auger).
15.FUNCTION FUELLING
16. The option “fuelling” (on the display it is shown “Charge Pellet”) is displayed on the menu only if the fireplace is off, for the auger to fill itself with pellets
beforehand. When the button 3
(Set)
is pressed, it changes the screen (see Fig. 8 – function for filling the auger). The button (
OK
) activates the function. It can
be stopped by pressing the button 5
ON/OFF
.
Fig. 8 Function filling the auger
16.CLEANING THE BURNER
The option “Cleaning the burner” (on the display appears “Cleaning”) displays on the menu only if the fireplace is off.
Button 3 (OK) activates the function, showing confirmation. The function cleaning of the burner is stopped by pressing button 3 again.
17.ACTIVATION OF THE PUMP
The function “Activation of the pump (“Start pump” is displayed) is displayed on the menu only if the fireplace is off and the HYDRO mode is enabled. It is
aimed at driving the circulation pump of the heating system for better and surer deaeration.
18.ALARMS
The alarms menu is displayed only if the warning condition is active or if an activated alarm is found out.
When you press button 3 (
Set
), there appears a list with the alarm conditions active at the moment. If more than one alarm are active, you can see them
using button 4. Table 8 lists alarm conditions, which can be displayed in the menu.
19.ALARM CONDITIONS
When an alarm condition occurs, on the screen an ALARM (see Fig.10) displays. In such situation you can't access the home screen and the status of the
fireplace can't be changed unless you give an unblocking command.
Fig. 10 Screen with activated alarm
The type of the alarm and the name are toggled on the lower line, and in the middle of the upper line “ALARM” flashes, while “information” and the code
of the alarm “Ahh” are constant. If button 5 is pressed for more than 2 seconds, the alarm will be cancelled after the processing the waiting time (see Fig.11).
After the command is cancelled, if the cause of the alarm has been removed, the display returns back to the START screen.
The status of the fireplace can be supervised also from the informational menu.
Fig. 11 Screen on canceling an alarm
Fig. 9 Filling the auger
By pressing button 1(
INFO
), the display shows a short description of the problem, which has arisen (Fig.12).
Fig.12 Screen with alarm indication
The display returns to the previous screen by pressing button
ESC
. If no button is pressed for 60 seconds, the display returns to the home screen.
Function Value
Activation of the temporary state
-5
÷
+5
Activation of the state of power
-5
÷
+5
Table 7 Correction of the performance of the auger