Battery Replacement
(Spinner® Chrono™ Power models only)
About
This procedure provides instruction to determine the condition of the battery and replacement
procedure.
Specifications
Battery Voltage
Specification
Battery Specification
6 VDC, 1.2 AH
GOOD battery state*
5.8 - 6.6 VDC*
LOW battery state*
5.5 - 5.7 VDC*
Console OFF state*
< 5.4 VDC*
Charging voltage
(while pedaling)
7.5 VDC max
Note: * static voltage measurements: no pedal movement and no
power adapter connected.
Determining the battery condition
If the measured voltage is below 5.5 vdc, charge the battery by pedaling greater than 55 rpm
(or using an optional battery adapter) until the battery static (non-pedaling) voltage level
reaches 5.8 to 6 vdc.
If the static battery voltage will not charge to and remain at 5.8 - 6 vdc: