Figure 222: Generator Belt
9
The generator belt gauge should read approximately 85
±
5 lbs. If
the belt tension is significantly high or low the belt tension
may be adjusted by loosening or tightening the
generator
mounting adjustment bolt. See
Drive Belt Gauge Instructions
(on page
142)
10
Loosen or tighten the generator adjustment nut and bolt until the
belt gauge reads approximately 85
±
5 lbs. See
Drive Belt Gauge
Instructions
(on page 142)
11
Tighten the two bolts that secure the generator mounting bracket to
the frame. Torque to 160 inch pounds