© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 341
Figure 295: Generator Belt
39
The belt gauge should read approximately 85
±5
lbs. If the belt
tension is significantly high or low the belt tension may be
adjusted by loosening or tightening the generator mounting
adjustment bolt. See
Drive Belt Gauge Instructions
(on page 142)
40
Loosen or tighten the generator adjustment nut and bolt until the
belt gauge reads approximately ±5lbs. See
Drive Belt Gauge Instructions
(on page 142)
41
Tighten the two bolts that secure the generator mounting bracket to
the frame. Torque to 160 inch pounds