Setting Up the Password (
pass
)
The
Password
menu is used for programming three
levels of security to prevent unauthorized changes to
the programmed parameter settings.
Protecting or Locking the Scanner
Enter the
Password
menu and program a six-digit
password.
Making Changes to a Password
Protected Scanner
If the scanner is password protected, the scanner will
display the message
Locd
(
Locked
) when the Menu
button is pressed. Press the Enter button while the
message is being displayed and enter the correct
password to gain access to the menu. After exiting
the programming mode, the scanner returns to its
password protected condition.
Disabling Password Protection
To disable the password protection, access the
Password
menu and enter the correct password
twice, as shown below. The scanner is now
unprotected until a new password is entered.
If the correct six-digit password is entered, the
scanner displays the message
unLoc
(
Unlocked
) and
the protection is disabled until a new password is
programmed.
If the password entered is incorrect, the scanner
displays the message
Locd
(
Locked
) for about two
seconds, and then it returns to Run Mode. To try
again, press Enter while the
Locked
message is
displayed.
Did you forget the password?
The password may be disabled by entering a
master password once. If you are authorized to
make changes, enter the master password 508655