Maintaining the pneumatic tool
49
CAUTION
There is a risk of environmental damage if the
lubricating oil is spilled.
Use a binding agent to clean-up spilled oil.
Wipe up bonded oil with cloths.
Dispose of cloths in accordance with the
legal guidelines applicable at the
implementation location.
Charging compressed air cartridges
Only fill empty KT-3500 compressed air cartridges with the PKT-
FILLMASTER 350 compressor.
Read the operating manual supplied with the compressor.
Test the compressed air cartridge
WARNING
Explosion hazard due to untested compressed
air cartridges.
Only use properly tested compressed air
cartridges.
KT-3500 compressed air cartridges must pass a pressure test at
PREBENA every five years. This test must be documented in the
proper field on the label of the compressed air cartridge. If you
recharge the compressed air cartridges yourself with the PKT-
FILLMASTER compressor, then you must send these cartridges in to
PREBENA. Otherwise this test is performed at PREBENA when
filling the compressed air cartridges.
Only use properly tested compressed air cartridges.