Wiring notes and recommendations:
•
Maximum line lengths of readers 1 and 2 (control unit reader) is 100 meters
•
Maximum RS485 bus length is 1000 metres.
•
Maximum RS232 line length of 10 metres.
•
Only use STP class 5 or FTP class 5 cables or superior.
•
Connect reader – control unit wiring shielding to the GND of the control unit to which the wiring
is connected.
•
Connect RS485 control unit – control unit wiring shielding with each other.
•
Never connect reader – control unit and control unit – control unit wiring shielding with each
other.
•
Never route system wiring in proximity to power cables.
•
Never exceed 1A consumption when using external readers.
•
Each control unit should be powered by the appropriate ALI13V8A3 or an equivalent power
supply unit with similar characteristics ( 13.8VDC, 3A)
•
Any electric locks or external relays must be powered separately (see next paragraph) and must
be fitted with tension suppressors (included)