3. Wiring 

MT4000-2 and MT10000-4 can be connected to a network of MT, TTD3000, M3000 or M5000 control units 
using the RS485 bus. 
Control unit configuration and access badge enable may be made via the keyboard and display (requires the 
optional keypad/display kit) or via the optional SWAMIGO software. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
Readers 1 and 2

: proximity, magnetic, radio or keypad readers can be connected to Wiegand 26, Wiegand 30, 

Wiegand 37, or Dataclock outputs. 
 

RS232

: a serial printer for the event printout or a PC/Notebook for firmware updating can be connected. 

 

RS485

: up to a maximum of 32 MT4000-2, MT10000-4, TTD3000, M3000 or M5000 control units can be 

connected to the bus. Use an INT485C converter for control unit network management via PC. 
 
Control unit or control unit network management via PC is made through the RS485 bus. Connection between 
the PC on which the SWAMIGO software is installed and the RS485 bus may be made via Ethernet, the RS232 
serial line, or the telephone line using INTETHERNET, INT485C, and INT485M converters, respectively, as 
shown in the following figure 

max 10 mt

RS232 

max 1000 mt. 

RS485

max 100 mt. 

Readers 1 and 2 

Relay outputs 
and digital inputs  

Содержание MT10000-4

Страница 1: ... Prastel S p A declines any responsibility in the event current standards in the country of installation are not complied with The symbol CE indicates conformity with Applicable European Directives MT4000 2 ACCESS CONTROL UNIT 2 DOORS 4000 USERS MT10000 4 ACCESS CONTROL UNIT 4 DOORS 10000 USERS ...

Страница 2: ...____________________________12 4 Management of Alarm Events ________________________________________________________13 4 1 Example of installation with management of alarm events _______________________________14 5 Control Unit programming and testing __________________________________________________16 5 1 Creating the site __________________________________________________________________16 5 2 ...

Страница 3: ...ntipassback control unit and user configurable User identification badge or badge PIN code from keyboard with keypad display kit MT10000 4 Power 12 VAC DC Consumption 100 mA Control Unit without accessories With the optional keypad display consumption is 200mA Operating temperature from 5 to 55 C Readers 4 external readers User capacity 10000 Event record 16000 Time slots 16 4 time intervals for e...

Страница 4: ...MT4000 2 MT10000 4 ISMTUK_06_06 doc Pag 4 2 Terminal strip board and connectors MT4000 2 Layout ...

Страница 5: ... V1 Power 12Vac dc maximum consumption 2A V2 Power 12Vac dc maximum consumption 2A GND Ground for reader powering and for the INT485C converter D D Interface 485 D D Interface 485 9V Positive for reader powering and for the INT485C converter D0 1 Reader 1 DATA0 line D1 1 Reader 1 DATA1 line D0 2 Reader 2 DATA0 line D1 2 Reader 2 DATA1 line IN1 Port 1 Output Pushbutton Input active with voltage 9V ...

Страница 6: ...ecause of incorrect system code Led TX RX Flashes when the control unit communicates on the RS485 bus Led ON OFF Red Æ control unit powered BATTERY Back up battery for keeping enablings in memory when the control unit is not powered life span 3 years with control unit not powered DISPLAY STRIP Strip for plugging in optional display KEYBOARD STRIP Strip for plugging in optional keypad LCD Trimmer f...

Страница 7: ... voltage 9V IN4 Port 4 Output Pushbutton Input active with voltage 9V IN5 Port 1 Break in Input active with voltage of 9V IN6 Port 2 Break in Input active with voltage of 9V IN7 Port 3 Break in Input active with voltage of 9V IN8 Port 4 Break in Input active with voltage of 9V NO1 Relay 1 N O contact COM1 Relay 1 common NC1 Relay 1 N C contact NO2 Relay 2 N O contact COM2 Relay 2 common NC2 Relay ...

Страница 8: ...er for the event printout or a PC Notebook for firmware updating can be connected RS485 up to a maximum of 32 MT4000 2 MT10000 4 TTD3000 M3000 or M5000 control units can be connected to the bus Use an INT485C converter for control unit network management via PC Control unit or control unit network management via PC is made through the RS485 bus Connection between the PC on which the SWAMIGO softwa...

Страница 9: ...ontrol unit wiring shielding with each other Never connect reader control unit and control unit control unit wiring shielding with each other Never route system wiring in proximity to power cables Never exceed 1A consumption when using external readers Each control unit should be powered by the appropriate ALI13V8A3 or an equivalent power supply unit with similar characteristics 13 8VDC 3A Any ele...

Страница 10: ...erminals IN1 and 9V of the control unit Using SWAMIGO software Duly configure reader 1 for relay 1 tripping Duly configure the IN1 input for relay 1 tripping Set relay 1 tripping and delay times to 1 and 0 seconds respectively Programme a badge for default access enable 5 Control Unit programming and testing pag 16 Electric lock is activated for 1 second following valid read or pushing of manual o...

Страница 11: ...opening button between terminals IN1 and 9V of the control unit Using SWAMIGO software Duly configure reader 1 for relay 1 tripping Duly configure the IN1 input for relay 1 tripping Set relay 1 tripping and delay times to 1 and 0 seconds respectively Programme a badge for default access enable 5 Control Unit programming and testing pag 16 Automatic door opens after 1 second following valid read or...

Страница 12: ...ISMTUK_06_06 doc Pag 12 3 3 Example of connection between two control units To connect more than one control unit to a single bus make the following connection Note Power the control units with separate power supply units ...

Страница 13: ...al alarm event and causes associated relay tripping Input IN5 is associated to reader 1 as a break in input along with relay R1 with a delay time of 0 and a triggering time of 5 seconds Input IN5 is associated to secondary relay R5 with delay and triggering times of 20 and 2 seconds respectively Input IN6 is not associated to any reader as a break in input and is associated to secondary relay R6 w...

Страница 14: ... Connect door electric lock to terminals NO1 and COM1 Connect opening contact to terminals IN5 deriving 9V of the control unit Connect the buzzer to terminals NO5 and COM5 Configure reader 1 for relay 1 tripping with break in input IN5 Configure reader 2 for relay 1 tripping with break in input IN5 Configure input IN1 for relay 1 tripping Configure input IN2 for relay 1 tripping Configure input IN...

Страница 15: ...o use an automatic door connect terminals NO1 and COM1 to the board of the automatic door Note 2 the figure shows the wiring with the terminal board of the MT10000 4 control unit but can easily be applied to an installation with a MT4000 2 control unit ...

Страница 16: ... link which was created on the desktop during program installation the Amigo activation dialog will appear Enter the licence code and key supplied together with the programme and press the green button to confirm If the entered codes are correct the program will be activated and the system access window will appear Type in the following codes and click the green button Operator ADMIN Password ADMI...

Страница 17: ...al Connect the powered control unit fitted with a badge reader to the PC via INT485C interface on data lines D0 1 and D1 1 Check that the description assigned to the previously created site appears in the yellow box on the toolbar If this is not the case use the Select Active Site item in the menu invoked by right clicking the mouse on the newly created site Click the button on the toolbar to open...

Страница 18: ...badges and assignment of authorisations Select the New Group item from the menu invoked by right clicking the mouse on the Badge Groups icon The following window will appear Type in the name to assign to the group e g GROUP1 and press ENTER Position the cursor on the Terminals field and click the button a list of the terminals will appear Double click to select a terminal from the list The system ...

Страница 19: ...hould sound a beep and display the badge code in the Badge Code field If this does not happen double check the connections and the terminal configuration Position the cursor on the User code field and press ENTER The create user window will appear accept the code suggested by the system and enter the details of the user then click the green button to confirm ...

Страница 20: ...Yes to the system message prompts Subsequent readings of the badge should generate a green line to appear in the events display area and the activation of relay 1 of the control unit If the green event description text does not appear double check the connections and the terminal configuration and repeat the procedure described in this chapter Badge enabled ...

Страница 21: ... the Flash file key and select the most updated version of the MTFlash hex file In the event of the upgrade calling for an EEprom file as well press the EEprom file key and select the most updated version of the MTEEprom hex file Press the Program on reset key The programme is now ready for upgrade transmission to the control unit Press the RESET key card top left hand corner of the control unit t...

Страница 22: ...ions retained perfectly unchanged Q My computer doesn t have a serial port what should I do R Use a commercially available USBÆRS232 converter Note Prolific converters are recommended as the system may not function with some commercial makes and models Q What type of printer can be connected to the MT ad TTD serial ports R A serial printer with a data reception capacity in the serial ASCII format ...

Страница 23: ...hes If the LED does not flash check the wiring D The PC on which was installed has been changed how can the old configuration be recovered R Install SWAMIGO in the new PC Replace the Amigo mdb database in the Amigo DB file with the copy taken from the old PC D The control unit loses the programming R If electrical locks are being used check that the connections are made as recommended in the insta...

Страница 24: ...re installed that compromise the integrity safety and operation of the product Only original spares must be used for repair or replacement of parts The installer must supply all information regarding the operation maintenance and use of individual components and of the system as a whole MAINTENANCE To guarantee the efficiency of the product it is essential that qualified professionals perform main...

Страница 25: ... tienen que estar ratificadas por documentos Estos documentos deben ser conservados por el usuario y estar siempre a disposición del personal competente encargado ADVERTENCIAS PARA EL USUARIO Leer atentamente las instrucciones y la documentación adjunta El producto tiene que ser destinado al uso para el que ha sido concebido Otro uso será considerado impropio y por tanto peligroso Además las infor...

Отзывы: